FOR YOUR SAFETY READ BEFORE LIGHTING
AWARNING
AWARNING
ACAUTION
BEFORE LIGHTING smell all around the appliance area for
gas, Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
The gas valve on the G60UHV(X) unit may be equipped
with either a gas control knob or gas control lever. Use only
your hand to push the lever or to turn the gas control knob.
Never use tools, If the knob will not tum or if the lever will not
move by hand, do not try to repair it. Call a qualified service
technician. Force or attempted repair may result in a fire or
explosion.
Placing the furnace
into operation:
G60UHV(X) units are equipped with an automatic ignition
system. Do not attempt to manually light burners on these
furnaces,
Each time the thermostat
calls for heat, the
burners will automatically
light, The ignitor does not get
hot when there is no call for heat on units with an automatic
ignition system,
AWARNING
Gas Valve Operation (Figures 26 and 27)
1 - STOP! Read the safety information at the beginning of
this section.
2 - Set the thermostat to the lowest setting,
3 - Turn off all electrical power to the unit,
4 - This furnace is equipped with an ignition device which
automatically lights the burners. Do not try to light the
burners by hand.
5 - Remove the upper access panel.
6 - White Rodgers 36E Gas Valve - Switch gas valve le-
ver to OFF. See figure 26.
Honeywell
VR8205 Gas Valve - Turn knob on gas
valve clockwise _
to OFF. Do not force. See figure
27.
7 - Wait five minutes to clear out any gas. If you then smell
gas, STOP! Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's instruc-
tions. If you do not smell gas go to next step.
WHITE RODGERS 36E SERIES GAS VALVE
HIGH FIRE
MANIFOLD
PRESSURE
ADJUSTMENT
ON SIDE
(under cap)
MANIFOLD
TAP ON SIDE
INLET PRESSURE
LOW FIRE MANIFOLD
TAP ON SIDE
PRESSURE
ADJUSTMENT
ON SIDE (under cap)
GAS VALVE SHOWN IN OFF POSITION
FIGURE 26
HONEYWELL VR8205 SERIES GAS VALVE
HIGH FIRE
ADJUSTING
SCREW
(under cap)
MANIFOLD
PRESSURE
TAP
LOW FIRE
(under cap)
INLET PRESSI
_E TAP
GAS VALVE SHOWN IN OFF POSITION
FIGURE 27
8 - White Rodgers 36E Gas Valve - Switch gas valve lever
to ON. See figure 26,
Honeywell
VR8205 Gas Valve - Turn knob on gas
valve counterclockwise
41_ to ON. Do not force, See
figure 27,
9 - Replace the upper access panel,
10- Turn on all electrical power to to the unit,
11- Set the thermostat to desired setting,
NOTE - When unit is initially started, steps 1 through 11
may need to be repeated to purge air from gas line,