TYPICAL G60UHV(X) FIELD WIRING DIAGRAM
USE COPPER
CONDUCTORS
ONLY.
D
_
FIELD INSTALLED
CLASS II 24V
FIELD INSTALLED
LINE VOLTAGE
t20V
ACC
G
N ...,,e-i.
LI ...,m.ili--
=
E
THERMOSTAT
$51
I@@@_)©@@1
=_
f
,
i
J
=
i
=
I
c .....
] _ ...............
L_t.U.._HH_-H2L _.H_-i
i. .........................
r ...............
I
t_----
J
_-e
24V IN_U'T ......
_
CQHBUSTIQN AIR
J84
INDUCE'R HOTOR
PR]HARY
P84
VALVE
oQ%o
GAS
BURNERS
HIGH HEAT
0
0
SVITCH
FLAME
SENSOR
3t59
RDLLOUT
__P159
RQLLDUT
$_/ITCH
$VITCH
SVITCH
PtSS
_
Tt
$21
_i
TRANSFOR_R
SEC_Y
LIMIT
INTEGRATED
CONTROL
!
2
..........
L._.
C_8
.........,,
, ,
_
?_1111
.d.-r-J-_..÷_-
I
I
HDTI_
t
FIGURE 24
TWO-STAGE, VARIABLE SPEED INTEGRATED CONTROL BOARD
I OOOq
STATUS =
E-COW-
DIAGNOSTIC
LEDs
HEATING
DIP
SWITCHES
sl
INDOOR
BLOWER DIP
SWITCHES
ON-BOARD
JUMPERS
1/4" QUICK
CONNECT
TERMINALS
HUM : 120 VAC OUTPUT TO HUMIDIFIER
XMFR : 12O VAC OUTPUT TO TRANSFORMER
LI
: 120 VAC INPUT TO CONTROL
CIRC : 120 VAC OUTPUT TO CIRCULATING BLOWER
EAC : 120 VAC OUTPUT TO ELECTRONIC AIR CLEANER
NEUTRALS=
120 VAC NEUTRAL
THERMOSTAT
CONNECTIONS
(TB1)
DS: DEHUMIDIFICATION SIGNAL
W2: HEATDEMAND F ROM2ND STAGET'STAT
Wl: HEAT DEMAND FROM IST STAGE T'STAT
R: CLASS 2 VOLTAGE TO THERMOSTAT
G: MANUAL FAN FROM T'STAT
C: THERMOSTAT SIGNAL GROUND CONNECTED TO TRANSFORMER
GROUND (TR) & CHASIS GROUND (GRD)
YI: THERMOSTAT Is_" STAGE COOL SIGNAL
Y2: THERMOSTAT 2nd STAGE COOL SIGNAL
0-- THERMOSTAT SIGNAL TO HEAT PUMP REVERSINGVALVE
H= 24V HUMIDIFIER OUTPUT
L= LENNOX SYSTEM OPERATION MONITOR
1= FUTURE USE
DIP SWITCH FUNCTIONS
HTG DIP SWITCH(ES)
1
2
3 and 4
INDOOR BLOWER
DIP SWITCH(ES)
FUNCTION
T'stat Heat Staqes (sin qle or two-staqe)
Second Staqe ON Delay (sin qle-staqe t'stat)
Heatinq Fan OFF Delay
FUNCTION
5 and 6
7 and 8
9 and 10
11 and 12
Coolinq
Mode Blower Speed
Blower Speed Adiustment
Cooling Mode Blower Ramping Profile
Heating Mode Blower Speed
FIGURE 25