Front View; Side View - Lennox G60UHV Series Installation Instructions Manual

Hide thumbs Also See for G60UHV Series:
Table of Contents

Advertisement

Return Air -- Upflow Applications
Return
air can be brought
in through
the bottom
or either
side of the furnace
installed
in an upflow application,
If the
furnace
is installed
on a platform
with bottom return,
make
an airtight
seal between
the bottom of the furnace
and the
platform
to ensure
that the furnace
operates
properly
and
safely. The furnace
is equipped
with a removable
bottom
panel to facilitate
installation,
Markings
are provided on both sides of the furnace cabinet
for installations
that require side return air. Cut the furnace
cabinet
at the maximum
dimensions
shown
on page 2.
NOTE
- When
air volumes
over
1800 cfm (850 L/s) are
required
with 60C or 60D models
in an upflow
applica-
tion,
the following
return
air options
are available:
1 - Return air from single side with transition
which will
accommodate
20 x 25 x I in. (508 x 635 x 25 ram) clean-
able air filter. (Required
to maintain
proper air velocity.)
See figure 7.
2 - Return air from single side with optional
RAB Return
Air Base. See figure 8.
3 - Return air from bottom.
4 - Return air from both sides.
5 - Return air from bottom
and one side.
Refer to Engineering
Handbook
for additional information,
Side Return Air
(with transition and filter)
20" X 25" X 1"
(508mm X635mm X 25mm)
Cleanable Filter
_/
Return Air
Plenum
FIGURE 7
Optional Return Air Base
(Upflow Applications
Only -- For use with B, C and D cabinets only)
J
t
AIR FLOW
14
"-_
L
7-1/4 (184)
v
I
17-1/2
(446) RAB-B
(98M60)
21 (533)
RAB-C
(98M58)
24-1/2
(622) RAB-D
(98M59)
FRONT VIEW
OPTIONAL
RAB
RETURN AIR BASE
7/8 .._
(22)
©
m
7
4
;-.91--
1 23 (584)
f
=1
102)1
Overall
1 Minimum
(Maximum)
11 (279)
I
2 Maximun_
1 Unit side return air
1A 1356)_
Opening
___
jl_ _ _
I
5-5/8
SIDE
RETURN
(143)
AIR OPENINGS
(Either
Side)
_1_
23 (584)
I
I
1 22-7-16
(570)
Overall
'Maximum)
_J_
._
_
3/4
(19)
91---
27-5/8 (702)
SIDE VIEW
NOTE- Optional
Side Return Air Filter Kits are not for use with RAB Return Air Base.
1 Both the unit return air opening
and the base return air opening
must be covered
by a single
plenum or IAQ cabinet.
Minimum
unit side return air opening
dimensions
for units requiring
1800 cfm or more of air (W x H): 23 x 11 in. (584 x 279 mm).
The opening
can be cut as needed
to accommodate
plenum
or IAQ cabinet
while maintaining
dimensions
shown.
Side return air openings
must be cut in the field. There are cutting
guides stenciled
on the cabinet
for the side return air
opening.
The size of the opening
must not extend
beyond the markings
on the furnace
cabinet.
2 To minimize
pressure
drop, the largest opening
height possible
(up to 14 inches)
is preferred.
NOTE- Optional
Side Return Air Filter Kits are not for use with RAB Return Air Base.
FIGURE 8
Page 10