Lennox G60UHV Series Installation Instructions Manual page 31

Hide thumbs Also See for G60UHV Series:
Table of Contents

Advertisement

TABLE 18
G60UHV-60C-090
BLOWER MOTOR PERFORMANCE
0.0" to 0.8" w.g. (0 through 200 Pa) External Static Pressure Range
Factory Settings: Heating Speed - 2; Cooling Speed - 4; Speed Adjust - NORM.
Return Air Options: Bottom; both sides; or bottom and one side.
"ADJUST"
Switch
Positions
Speed Switch Positions
Second Stage "HEAT" Speed
Second Stage "COOL"
Speed
1
2
3
4
1
2
3
4
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1570
740
1770
835
1965
925
2185
1030
1680
795
1795
845
2015
950
2255
1065
NORM
1425
675
1625
765
1810
855
1990
940
1520
715
1635
770
1855
875
2065
975
--
1270
600
1435
680
1635
770
1790
845
1355
640
1460
690
1670
785
1845
870
"ADJUST"
First Stage "HEAT" Speed
First Stage "COOL"
Speed
Switch
1
2
3
4
1
2
3
4
Positions
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1430
675
1625
770
1815
855
1990
940
1170
550
1250
590
1425
670
1600
755
NORM
1290
610
1470
695
1660
780
1830
865
1060
500
1140
540
1280
605
1445
680
--
1165
550
1300
615
1470
695
1635
770
930
440
1015
480
1155
545
1285
605
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately
91% of the same second stage HEAT speed position.
First stage COOL (two-stage air conditioning
units only) is approximately
70% of the same second stage COOL speed position.
Continuous
Fan Only speed is approximately
38% of the same second stage COOL speed position - minimum 500 cfm (235 L/s).
Lennox Harmony Ill ' Zone Control Applications
- Minimum blower speed is 478 cfm (225 Us).
TABLE
19
G60UHV-60C-090
BLOWER
MOTOR
PERFORMANCE
0.0" to 0.8" w.g. (0 through
200 Pa) External
Static Pressure
Range
Factory
Settings:
Heating
Speed
- 2; Cooling
Speed
- 4; Speed
Adjust
- NORM.
Return Air Options:
Single
side return air - Bold volumes
require
field-fabricated
transition
to accommodate
20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable
air filter
in order to maintain
proper
air velocity
across
the filter.
"ADJUST"
Switch
Positions
Speed Switch Positions
Second Stage "HEAT" Speed
Second Stage "COOL"
Speed
1
2
3
4
1
2
3
4
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1520
715
1705
805
1910
900
2120
1000
1605
760
1745
825
1955
925
2195
1035
NORM
1380
650
1540
730
1750
825
1925
910
1475
695
1565
740
1785
840
1985
935
i
1230
580
1395
660
1570
740
1745
825
1305
615
1410
665
1590
750
1795
845
"ADJUST"
First Stage "HEAT" Speed
First Stage "COOL"
Speed
Switch
1
2
3
4
1
2
3
4
Positions
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
cfm
L/s
+
1385
655
1560
735
1765
835
1945
920
1125
530
1210
570
1370
650
1525
720
NORM
1255
590
1425
670
1580
745
1785
840
1020
480
1100
520
1235
580
1385
655
i
1135
535
1265
600
1430
675
1570
740
890
420
980
465
1115
525
1235
580
NOTES - The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately
91% of the same second stage HEAT speed position.
First stage COOL (two-stage air conditioning
units only) is approximately
70% of the same second stage COOL speed position.
Continuous
Fan Only speed is approximately
38% of the same second stage COOL speed position - minimum 500 cfm (235 L/s).
Lennox Harmony Iit"
Zone Control Applications
- Minimum blower speed is 478 cfm (225 L/s).
Page 31