HEATING SEQUENCE OF OPERATION
NO
NO
I
FIRST-STAGE
(LOW
F,RE)PRESSURE
I
SWITCH CLOSED WITHIN 2.5 MINUTES?
YES
_
15-SECOND
COMBUSTION
AIR INDUCER
I
m
PRE-PURGE
INITIATED BY CLOSED FIRST-STAGE
i
PRESSURE
SWITCH (or 15 SECOND
INTER-PURGE
PERIOD.)
STATUS LED -- HEARTBEAT.
[
IGNITOR
WARM-UP
I_0 S ECONDSt J
STATUS LED -- HEARTBEAT.
YES
_
I
is IGNITOR INTACT AND CONNECTED?
i
YES
I
AT END OF IGNITOR 20 SECOND WARM UP
I
I
PERIOD, 4-SECOND TRIAL FOR IGNITION.
I
GAS VALVE OPENS, IGNITOR ENERGIZED
DURING
4-SECOND
TR AL UNT L FLAME SENSED,
YES
I
4-SECOND
FLAME STABILIZATION
PERIOD.
I
NO
I
FLAME RECTIFICATION
CURRENT CHECK
CAN FLAME BE PROVEN WITHIN 4
SECONDS AFTER GAS VALVE OPENS?
( > 0.20 microamps)
FLAMEyES PRESENT?_
IN--_-_°
CONTINUED ON NEXT PAGE
J
I
[
---4
THERMOSTAT
CALLS FOR HEAT
STATUS LED - HEARTBEAT.
(Refer to box A on previous page)
GAS VALVE OFR COMBUSTION
AIR INDUCER
OFF. INDOOR BLOWER OFF. UNIT WILL RETRY
AFTER 5-MINUTE WAIT PERIOD,
STATUS ERROR CODE 2 + 3.
COMBUSTION
AIR INDUCER OFF, IGNITOR OFF.
SIGNAL HOLDS UNTIL IGNITOR IS REPLACED
OR RECONNECTED,
STATUS ERROR CODE 4 + 7.
IS VOLTAGE ABOVE 90 VOLTS?
.o_
COMBUSTION
AIR INDUCER OFF, IGNITER OFF.
SIGNAL HOLDS UNTIL VOLTAGE RISES ABOVE 95
VOLTS, STATUS ERROR CODE 4 + 8.
GAS VALVE OFF. COMBUSTION
AIR
Lt
_r
INDUCER ON. INDOOR BLOWER OFF.
I
STATUS LED -- HEARTBEAT.
HAS CONTROL FAILED TO SENSE
FLAME FOR FIVE CONSECUTIVE
TRIES
NO
DURING A SINGLE HEAT DEMAND?
YES lr
WATCHGUARD
MODE. GAS VALVE OFF,
COMBUSTION
AIR INDUCER OFR
INDOOR BLOWER OFF.
STATUS ERROR CODE 4 + 1.
IS 60-MINUTE
RESET PERIOD COMPLETE?
YES _
HAS CONTROL
RESET IGNITION SEQUENCE
FOUR (4) TIMES?
WATCHGUARD
MODE,
STATUS ERROR CODE 4 + 3.
I
J
I
YES
NO