Datavideo HS-1600T MKII Instruction Manual page 73

4 channel hd/sd hdbaset portable video streaming studio
Hide thumbs Also See for HS-1600T MKII:
Table of Contents

Advertisement

illuminate red.
 Different version number detected: The BLK button flashes red twice and the firmware will be
updated. All six program row buttons will illuminate red while the firmware is being updated.
As soon as the program row buttons are turned off and then turned back on (red) again, the
firmware update is complete. The HS-1600T MKII automatically reboots itself after the
keyboard firmware is updated.
5. The Mainboard firmware is automatically updated after the Step 4 is executed and the update
status will be indicated by the LED color (green) of the preview row buttons. Approximately 5
seconds after the HS-1600T MKII is rebooted, you will see a startup screen on the monitor with old
mainboard version (V1.5) displayed at the bottom right corner. At this point, the BLK button will
start flashing green. The mainboard firmware update will start approximately 10 seconds after the
mainboard finishes booting.
The startup screen on the monitor disappears and the firmware update will be in progress as the
preview row buttons are turned on one at a time from left to right until all buttons illuminate solid
green after approximately ONE minute. At this point, the firmware update is complete and the
mainboard will reboot itself. After the HS-1600T MKII finishes booting, the new version number
(V1.6) will be displayed at the bottom right corner of the HS-1600T MKII startup screen.
6. The OSD fonts will be automatically updated after the Step 5 is executed and the update status
will be indicated by the LED color (green) of the preview row buttons. The machine reboots itself
after the mainboard is updated, and the BLK button will start flashing green after the reboot. The
OSD fonts update will start approximately 10 seconds after the mainboard finishes booting.
The startup screen on the monitor disappears and the firmware update will be in progress as the
preview row buttons are turned on one at a time from left to right until all buttons illuminate solid
green after approximately SIX minutes. At this point, the monitor should display a four-quadrant
Multiview screen and this indicates that the OSD fonts update is complete.
7. The update is finished when all six buttons of the program and preview rows illuminate solid red
and green respectively. Remove the USB thumb drive and reboot the HS-1600T MKII.
8. After the machine finishes booting and as soon as you see the Multiview screen, press the MENU
button to open the OSD menu to check the MB, OSD and KB versions:
Use the Up/Down arrow buttons to move to the Setup option and check if the firmware is
successfully updated:
 MB Software: V1.16.1.02
 KBD Software: V1.2 (HS-1600T MKII)
Note 1: The device will not be damaged even if the USB cable or power is accidentally disconnected
while the firmware is being updated; plug the USB thumb drive back in and reboot the device to
resume the update process.
Note 2: The USB disk drive system supports FAT / FAT32 formats.