Cable Connection/Disposition; Control Digital System - Sony FLEXICART BFC-1 Installation Manual

Multi cassette system
Hide thumbs Also See for FLEXICART BFC-1:
Table of Contents

Advertisement

4-13. CABLE CONNECTION/DISPOSITION

4-13-1. Control Digital System

PC
The Connection for control VTR/SWITCHER at inside of the cart
machine is shown in this figure.
When these equipments are controlled directly without through the
cart machine, use connecter 1 and 3 of the IF-373 board. In this
case, the cart machine watch the state of these equipments only.
connecter 1:
use for control the equipments connected con-
necter 2
connecter 3:
use for control the equipments connected con-
necter 4
example) The case of IF-373 board of SLOT 5.
Connecter 1 is used for direct control of VTR1.
Connecter 3 is used for direct control of VTR2.
When five or six VTRs are installed, connect the VTRs to BKFC-
100 (IF-373; Optional) of SLOT-7.
SLOT-7 CN2 (VTR5)
CN4 (VTR6)
4-60
D9M
RS-232C (2)
FLEXICART
CPU-107
D9F
1 (RS-422A)
D25F
2 (RS-232C)
D25F
3
IF-373
(SLOT-8)
IF-373
(SLOT-5)
IF-373
(SLOT-6)
BKFC-100
(OPTION)
1
D9F
D9F
2 (SW'ER)
3
D9F
4
D9F
1
D9F
D9F
2 (VTR1)
3
D9F
D9F
4 (VTR2)
1
D9F
D9F
2 (VTR3)
3
D9F
D9F
4 (VTR4)
BFC-1