LD 17 – Configure the ISL D-channel for the DCHIP card (Large and Small Systems)
(Part 2 of 2)
Prompt
Response
GRP
x
DNUM
xx
CDNO
xx
PORT
x
...
USR
ISLD
IFC
SL1
ISLM
382
...
SIDE
USR
Install and configure IP Trunk 3.01 (and later) node
Description
Network Group number = 0 – 4. Applies to Meridian 1
PBX 81C CP PII/CS 1000M MG without Fiber Network
Fabric (FNF) only.
Network Group number = 0 – 7. Applies to Meridian 1
PBX 81C CP PII/CS 1000M MG with FNF only
Device Number for I/O ports= 0 – 15.
Applies to MSDL cards only.
Card Number where DCHI resides for Small System, CS
1000S system, Media Gateway 1000B, and Media Gateway
1000T.
Port number = 0 – 3 for MSDL card
Chassis/CS 1000M Cabinet
User
Interface type for D-channel
Maximum number of Integrated Service Signaling Links
Meridian 1/CS 1000M node type
Note: The IFC response entry must have the protocol entered in OTM's
ITG Node Properties – Card Configuration Protocol pull-down menu.
The MSDL card does not apply to Meridian 1 PBX 11C Cabinet/CS 1000M
Cabinet and Meridian 1 PBX 11C Chassis/CS 1000M Chassis; therefore the
DCGI prompts and responses apply. The feature requires the option switches
on the Cabinet system SDI/DCH card to be set for RS-422 mode operation.
= 1 or 3 for DCHI on Meridian 1 PBX 11C