Transition
Connector
16"
(406mm)
Fig. 34 Minimum lintel height for flush or forward placement.
Fireplace Installations Using Existing Wood Stove Chimneys
ST379a
SDVR
Min. fireplace installation
6/00
Existing Wood Stove
Chimney Pipe
Finished Combus-
tible Wall
20¹⁄₂"
(521mm)
* Transition pipe must be at least 6" (152
mm) from any combustible material.
Fig. 35 Installations using existing wood stove chimney pipe.
20012950
Fireplace Installation Requirements
26"
(660mm)
ST379a
*
6"
(152mm)
ST713a
SDVR
existing stove chimney
3/02
Stardance Direct Vent - Rear Vent Gas Heaters
Existing Vent Pipe
Field
Fabricated Cover
Transition Connector
"X" must be 6" (152 mm) from any combustible material un-
ST713a
less completely covered by field fabricated sheet metal. If
3" vent pipes are covered by sheet metal, the clearance to
combustibles may be 2" (51 mm).
Transition
Connector
26"
(660mm)
20���"
(521mm)
ST380a
SDVR
min. lintel height
6/00
X
ST714
SDVR
thru fireplace
chimney wall
4/02
ST380a
ST714
21