Stardance Direct Vent - Rear Vent Gas Heaters
A two-part square trim plate is provided to give a fin-
ished look once installed. Simply fit the two halves of
the trim plate around the cathedral ceiling support box
hanging below the ceiling (overlapping if necessary)
and screw them to the ceiling. Both the ceiling support
and cathedral ceiling support can support a maximum
of 40' (12 m) of pipe.
Offsets:
If any offsets are necessary in the vertical system, an
Offset Support (OS) should be installed directly above
the upper elbow of the offset. Install by attaching the
offset support band to the pipe with two #8 x 1/4" sheet
metal screws (minimum ) and secure the offset support
straps to surrounding structure. (Fig. 40)
Offset Support
Strap
Fig. 40 Offset support.
ST945
Appliance
Adapter (AAV)
Pipe
Length
�����
������� �������
Nail to top of
framing
Offset Support
Collar
�����
����� ������ �������
����
ST946
ST927