Vermont Castings SDDVRBD, SDDVRC, SDDVRCCB Installation And Operating Manual page 17

Vermont castings stardance direct vent, rear vent gas heate operating manual sddvrcb, sddvreb, sddvrmb, sddvrbs, sddvrch, sddvrvg, sddvrbd sddvrc series: sddvrccb, sddvrceb, sddvrcmb, sddvrcbs, sddvrcch, sddvrcvg, sddvrcbd
Table of Contents

Advertisement

Vent Opening - Combustible Wall
9³⁄₈"
(240mm)
9³⁄₈"
(240mm)
Vent Opening - Noncombustible Wall
7¹⁄₂"
(191mm)
Fig. 23 Locate vent opening.
Attach the firestop plate to the sleeve end with the
holes. (Fig. 24) NOTE: The wall sleeve is required
in combustible walls only.
3. Install the Wall Firestop/Sleeve assembly into the
wall cutout and fasten the firestop to the wall cutout
framing members. (Fig. 24)
VO584-100
12"
Vent Opening
(305mm)
Max. Length
2/99 djt
Fig. 24 Assemble the wall sleeve and firestop.
4. If necessary, measure to determine the vertical
length (X) of pipe required from the first (transition)
ZCS103
elbow to the wall cutout centerline, including a 2"
Zero Clearance Sleeve
overlap at the joint. (Fig. 25) Use a hacksaw or tin
& Firestop
12/6/99 djt
snips to trim the pipe as needed.
5. Install first the inner then the outer straight pipe
section(s), trimmed end down, to the point of the el-
bow. Drill 3 holes through each joint and fasten with
sheet metal screws.
6. Install the elbow using 3 sheet metal screws at each
joint.
7. Measure, and cut if necessary, the appropriate
length of pipe section needed to make the connec-
tion through the wall. Include a 2" overlap; i.e. from
the elbow to the outside wall face, about 2" or the
distance required if installing a second 90° elbow.
(Fig. 26)
20012950
VO584-100a
Sleeve
#8 Sheet
Metal Screws
Firestop
ZCS103
Stardance Direct Vent - Rear Vent Gas Heaters
Fig. 25 Determine the vertical pipe length.
X
Fig. 26 Measure the horizontal length.
8. Slip the wall plate and trim collar over the interior
end of the horizontal pipe and install into the wall
sleeve. Seal the joint inside the wall plate if needed
to keep cold air from being drawn into the home.
9. Connect the horizontal pipe to the elbow. Fasten the
wall plate to the pipe with three sheet metal screws.
Slide the trim collar up against the wall plate to cover
the screws. (Fig. 27)
Wall
Sleeve
ST216
Fig. 27 Install the horizontal pipe and wall plate parts.
ST216
install pipe thru wall
12/6/99 djt
X
ST214
measure vertical vent
12/6/99 djt
ST215
measure thru wall
12/6/99 djt
Trim Collar
Wall Plate
ST478
ST215
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents