Figure 6.7.6 Vco Free-Run Frequency Adjustment; Figure 6.7.7 Pre-Adjustment Of Servo Signal - Fujitsu M2361A Customer Engineering Manual

Mini-disk drive
Table of Contents

Advertisement

(2)
Static Adjustment
d.
VCO free-run frequency adjustment (RV7)
CD
Trigger
by
itself at the positive-going edge.
Qj
Adjust the potentiometer RV6 so that the following Tvco is 102
ns±S ns.
L_~TVCO
_ - I
Tvco
=
l02ns!5ns
Figure 6.7.6
VCO Free-Run Frequency Adjustment
h.
Pre-Adjustment of Servo Signal
(J)
Connect the CNB-34 to an oscilloscope.
CD
Trigger
by
itself and adjust the potentiometer RVI coarsely so
that the signal amplitude is 7.0V±O.SV (peak-to-peak).
Refer to
Figure 6.7.7.
CNB-34 (CRAMP)
7V
±O.SV
pop
Figure 6.7.7
Pre-Adjustment of Servo Signal
c.
Timer Gate Adjustment (RVS)
CD
Connect the CNB-32 to an oscilloscope.
CD
Trigger
by
itself at the negative-going edge.
CD
Adjust the potentiometer RVS so that the following TTC is
320nx±lOns.
B03P-4S2S-0002A ••• 02
6 - 27