1.2.3 Power Requirements - Fujitsu M2361A Customer Engineering Manual

Mini-disk drive
Table of Contents

Advertisement

1.2.3 Power requirements
Table 1.2.3 Power requirements (Typical values)
Voltage
Frequency
Current (Aac)
Power
Heat dissipation
(Vac±lo\)
(Hrl2Hz)
Consumption
Starting'"
Running
(kVA)
Kcal/hour
BTU/hour
100
7.8/7.3
6.0/5.7
0.60/0.57
470/440
1,800/1,700
120
6.5/6.3
4.8/4.6
0.57/0.55
440/430
1,700/1,600
200
50/60
4.3/3.8
3.1/3.0
0.62/0.60
480/470
1,900/1,800
220
4.1/3.6
2.9/2.8
0.64/0.62
500/480
2,000/1,900
240
4.0/3.5
2.6/2.5
0.62/0.60
480/470
1,900/1,800
*
Worst case transient with a maximum of 40 amps for less than 1/2 cycle
of input AC power.
Refer to Figure 1.2.2.
40 -
6.3-
4.6-
Worst case
~
transient
~
L
8.3
ms max
(60 Hz)
-, r
10.0
ms max
(SO Hz)
I
40
Seconds (approx)
Figure 1.2.2
AC start/run current curve (6.3 amps and 4.6 amps
are for 120 Volt 60 Hz· case)