Remote/Local Switch; Rltm/Absl (Release Timer/Absolute) Switch; Mrtz (Manual Rtz) Switch; Figure 3.4.2 Spindle Sequence Pick/Hold Timing - Fujitsu M2361A Customer Engineering Manual

Mini-disk drive
Table of Contents

Advertisement

3.4.1
REMOTE/LOCAL switch
When this is set to Remote, the spindle motor starts/stops rotating in
accordance with the commands (Spindle Sequence Pick/Hold) issued from the
controller.
Refer to Figure 3.4.2.
When set to Local, rotation is under the
control of the Start switch on the operator panel.
I~----------------------------------------------~
-tf-
1 Oms min.
"---
SppiDd
t
Ie Sequence
II
r-
-------------.1,_-_-
_-_~~:,,...J
_-_-_-_-_-_..., ..... : _ _ _ _ _ _ _ _ _
AC Input
Ie
.1
II_
"
o
min.
Spindle Sequence
,r-----------------",'l/------
Hold
---.J
----_____ _
Spindle
Starl/
SlOP
Sequence
Drive .0
Drive #1
Last Drive
_ _ _ ..J
l
Stut
'\
____ I-..JI
Start
S
!itt.
_~_j:.>"
"
"
,,------,
___________ 1
Start
Stop
~~
I)
Stop
I I
71
SlOP
Figure 3.4.2
Spindle sequence pick/hold timing
3.4.2
ENABLE/DISABLE A, B switch
The A-channel, or if the dual port option is used, the B-channel, interface
signals can be enabled/disabled.
3.4.3
RLTM/ABSL (Release Timer/Absolute) switch
This switch is functional if the dual port option is provided.
When the switch is in RLTM, reserved status will be released 500 ms after Unit
Select Command if the Release Command has not already been isued.
When the
switch is in ABSL, reserved status can be released only by the Release Command.
3.4.4
MRTZ (Manual RTZ) switch
The head performs RTZ operation when this maintenance-aid switch is pressed.
B03P-4825-0002A ... OlA
3 - 7