Diagnosis and service checks

Calling up messages (message history)

The messages are sorted by date.
Tap the following buttons:
1. "
"
2. "Service"
3. Enter password "viservice".
4. Use
to confirm.
5. "Message history"
The following is displayed in the message lists:
Date and time of the occurrence of the notifica-
tion
Notification number
Description of the notification
Subscriber number of the component on which
the message has occurred:
PlusBus subscriber components
0
EM-S1 extension (ADIO electronics
module)
1 - 15
EM-M1, EM-MX and EM-P1 extensions
(ADIO electronics module)
17 - 31 EM-EA1 extension (DIO electronics
module)
32 - 47 Cylinder module (electronics module
M2IO)
49 - 63 Vitotrol 200-E
64
SDIO/SM1A electronics module
CAN BUS subscriber components
1
HMU heat management unit
50 BCU burner control unit
58 RF module (wireless module)
59 HMI programming unit
60 Fan unit
90 Gateway
Low power radio subscriber components
49 - 63 Vitotrol 300-E

Checking outputs (actuator test)

Note
When the actuator test is started, all actuators are ini-
tially disabled and valves moved to their central posi-
tion.
82
6.
"Faults" to call up saved fault messages. For
further details, see the following chapter "Fault
messages".
"Service messages" to call up saved service
messages.
P.1 Maintenance due after interval
P.4 Top up heating water.
P.8 Maintenance due after burner hours run.
"Status", to call up the saved status messages.
S.60 Summer mode active (outside temperature
economy function)
S.74 Heating suppression, heating
S.75 DHW circulation pump active
"Warnings" to call up saved warning messages.
A.11 System pressure has fallen below the
standard range
Measure: Check system pressure and dia-
phragm expansion vessel. Check settings
for set system pressure and range in the
commissioning assistant.
A.12 Real time clock battery flat.
Measure: Replace the battery
(type CR2032) in the HMU heat manage-
ment unit.
A.18 Possible condensate backup in the heat
cell
Measure: Check the combustion chamber
and condensate drain.
A.20 Service interval could not be activated.
Measure: Check the time and date set-
tings.
A.21 System pressure has exceeded maximum
pressure.
Measure: Check safety valve and dia-
phragm expansion vessel.
On combi boilers: Check plate heat
exchanger
"Information", to call up saved service informa-
tion.
I.56 External demand active
I.57 External blocking active
I.59 Parameters have been restored (parameter
set was flashed to BCU electronics mod-
ule).
7. If you wish to delete the messages, tap .
8.
to confirm
Tap the following buttons:
01. "
"
02. "Service"
03. Enter password "viservice".

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B2hfB2kf

Table of Contents