Function description

Interval function, solar circuit pump

For correct capture of the collector temperature, the
interval function cyclically switches on the collector cir-
cuit pump briefly.

External heating circuit hook-up (if installed)

Note
Only in conjunction with weather-compensated opera-
tion.
120
See parameter 1719.0
Function:
If the external demand is active (plug 96 or digital
input on DIO electronics module closed), the heat-
ing circuit is supplied with heat.
If the external demand is inactive (contact open),
heat supply to the heating circuit ends (regardless
of current set room temperature or the switching
time).
!
Please note
There is no frost protection for the connec-
ted heating circuits.
Connection:
If just one heating circuit is web connected, use
plug 96. See page 26
If several heating circuits (max. 3) are web connec-
ted, all contacts are connected at EM-EA1 exten-
sion (DIO electronics module).
See EM-EA1 extension installation instruc-
tions