  – Do not start SensorControl Plus a 
second time with ingredients which have 
already been processed.
Example: Making beaten egg
white with SensorControl Plus
X Image sequence J
1. Prepare the base unit and insert the 
professional stirring whisk.
2. Press the release button and push the 
swivel arm down until it locks into place.
3. Plug the mains plug into the mains. 
"OptiMUM" appears on the display.
4. Separate the eggs (2-12 eggs).
5. Press button D. "CREAM" appears on 
the display. 
Note: Models without a scale display 
"CREAM > 300 ml". Press button D 
again. "CREAM > 700 ml" appears on the 
display.
6. Press button D. "EGG WHITE" appears 
on the display.
7. Add the egg white to the bowl. "TURN
SWITCH TO M/A" appears on the display. 
8. Turn the rotary switch to ü and hold 
in this position.
9. After a short while the rotary switch is 
automatically fixed in this position and 
remains on ü after being released.
10. "SENSOR CONTROL PLUS" appears 
on the display. SensorControl Plus 
monitors the processing.
11. Once the pre-programmed consistency 
has been achieved, an acoustic signal 
will sound and processing will stop. 
"FINISH" appears on the display.  
Note: Setting the acoustic signal 
X "Settings" see page 9
12. The rotary switch automatically switches 
to y. "OptiMUM" appears on the 
display.
13. Disconnect the mains plug. 
14. Processing with the "EGG WHITE" 
function is ended.
15. Clean all parts immediately after use. 
X "Cleaning and maintenance" see
page 15

Using the scales

Depending on the model in question, the 
appliance may be equipped with scales. 
The following applications are possible:
  – Weighing the added ingredients 
(either each ingredient individually or all 
ingredients together).
  – Pre-setting a desired weight and 
counting down until sufficient ingredients 
have been added (with audible 
information signals).
Important:
  – The appliance has 4 weight sensors 
in the feet. The scales only supply 
the correct results if all of the feet are 
standing on a solid and level surface. 
Do not put any cloths or other items 
underneath. 
  – Do not slide the appliance about on 
the work surface as this may impair the 
functioning of the scales. To move the 
appliance, lift it.
  – After switching on or resetting the 
scales, they are calibrated for a brief 
moment (tare). During this process, do 
not touch the appliance or place any 
items on top of it (e.g. wooden spoon, 
tea towel etc.). 
  – Ensure that measuring jugs or 
packaging are not lying on top of the 
appliance (e.g. on the edge of the filling 
shaft).
Weighing ingredients
X Image sequence K
1. Prepare the base unit.
2. Plug the mains plug into the mains. 
"OptiMUM" appears on the display.
3. Press button C and don't touch the 
appliance again.  
Individual dashes appear one after each 
other on the display during calibration: 
"– – – – –" (tare). 
4. "0 g" or "0.00 lb" appears on the display 
(depending on the setting). The scales 
are ready.
5. Add ingredients. The scales display the 
weight.
Using the scales