Troubleshooting - Dimplex Edel EDL200UK-630 Installation And User Instructions Manual

Air source heat pump water heater
Table of Contents

Advertisement

8.3

Troubleshooting

Issue
The Heat Pump is not
working
No Hot Water
Condensates are not drain-
ing
Electrical backup is not
working
Do not adjust the settings on the thermostat.
Reset button (85
Check
- That the desired water temperature is higher than
the
temperature of the water in the tank.
- There is power supply to the appliance.
- The the green light is on.
- That the appliance is not in holiday mode (see
Section
7.6)
- That the air intake or ambient temperature is under
- 7 o C or over +35 o C.
- That the timer has not been programmed to stop
the
appliance operating ('Economy' light will be on (see
Section 7.2).
- If an error message is displayed on the screen
(see Section 8.5).
- That the volume consumed is not higher than the
volume in the tank.
- The time period the appliance operates is not too
short (12hrs minimum if connected to piping).
- The water temperature is not set too low.
- The draining system for dirt or blockages:
Remove the cover (see Section 6.9.1) and check
the
opening.
- That tubes do not have bends or "U" shapes that
can
collect water.
- That the end of the tube is not blocked off and has
access to open air.
- That your electricity provider or your timer is not
preventing the appliance from functioning, 'Econo-
my'
symbol should be on (see Section 7.2).
- A heat-limiting safety thermostat for electrical
backup has not been activated after over-heating
(>85°C). If this is the case, reset it.
- Before resetting, check:
• that the heating element does not have limescale.
• clean or replace if necessary.
Table 5: Troubleshooting
o
C) on thermostat
Troubleshooting