7.10 Programming

Programming enables you to define the periods of time the appliance runs in 'Economy', 'Comfort' or 'Off' mode
(freeze protection mode). Electrical backup is not allowed while the appliance is in 'Economy' mode.
To access the program menu:
- Press the 'Clock'.
- Press down for 3 seconds until the screen display 'Settings'.
MONDAY
NEW PROG.
COPY SUN.
COPY PROG.
MODIFY PR.
SEE PROG.
Heating time for the tank varies according to the outdoor temperature.
Select Day
0000-_ _ _ _
00 : 30
h
time period
= Copy Programming from day before
= Copy a standard programme or a programme from another day
= Modify exisitng programme
= See exisitng programme
Set-Up and Use
0000-0630
frost pt
Set comfort
time period
Frost PT = Frost Protection Mode
ECO = Heat Pump Only Running
CONF = Heat Pump Only Running +
electrical back-up if needed
0630-_ _ _ _
06 : 30
h
Set end of
second time
period
...and so on, up
to 7 time periods
per day