Installing A Ran Up Converter (Ruc2.X Or Ruc3) Module - ADC Digivance NXD Installation And Maintenance Manual

Radio access node (ran)
Hide thumbs Also See for Digivance NXD:
Table of Contents

Advertisement

ADCP-75-210 • Issue 1 • March 2007
3. Slide the RDC module into the designated slot within the RAN chassis.
4. Lock the IEL handles on the top and bottom of the RDC module into the chassis and
tighten the handle screws.
5. Using an SMA coaxial cable (1955000P081), connect one end to the PRI IN port on the
RDC module and the other end to the appropriate P OUT port on the C/MCPLR or P/
MCPLR module. Each P OUT port is associated with a different band.
Note: For more information on the C/MCPLR module ports, see
Multicoupler (C/MCPLR), on page
ports, see
6. Using an SMA coaxial cable (1955000P081), connect one end to the DIV IN port on the
RDC module and the other end to the appropriate D OUT port on the C/MCPLR or P/
MCPLR module. Each D OUT port is associated with a different band. For more
information on these ports, refer to the sections identified in the note above.
4.1.6

Installing a RAN Up Converter (RUC2.X or RUC3) Module

The RAN Up Converter (RUC2.X or RUC3) module may be installed into either of two slots in
the RAN chassis, depending on the band for which the module will be used. One module is
required for each two bands. The two slots are:
• Slot 11 (labeled RUC A2): used for first and second bands
• Slot 14 (labeled RUC A5): used for third and fourth bands
Page 64
© 2007, ADC Telecommunications, Inc.
Section 1.7.10, 1900 MHz Multicoupler (P/MCPLR), on page
Figure 45. Installing an RDC Module
20. For more information on the P/MCPLR module
Section 1.7.9, 800 MHz
22.
21235-AX

Advertisement

Table of Contents