Ran Cabinet - ADC Digivance NXD Installation And Maintenance Manual

Radio access node (ran)
Hide thumbs Also See for Digivance NXD:
Table of Contents

Advertisement

ADCP-75-210 • Issue 1 • March 2007
ITEM
Input IP3
Received signals
In band
Out of band +/- 8.5 MHz
Out of band +11/-13 MHz
Out of band +13/-16 MHz
Automatic gain control
Detector integration time
Attack time
Decay time
Gain control range
Gain in series with BTS
Gain parallel to BTS
Gain stability
System Bandwidth
Forward Path
Reverse Path
Impedance
Output Power
Cellular/SMR 10 Watt MCPA
PCS 20 Watt MCPA
Gain resolution
Gain measurement
Note: The Manufacturer's rated output power of this equipment is for single carrier
operation. For situations when multiple carrier signals are present, the rating would have
to be reduced by 3.5 dB, especially where the output signal is re-radiated and cause
interference to adjacent band users. The power reduction is to be by means of input power
or gain reduction and not by an attenuator at the output of the device.
1.6

RAN Cabinet

The RAN cabinet is a NEMA-3R enclosure designed to protect its electronic components from
weather and human tampering. The cabinet is weather-tight but contact with salt-air mist should
be avoided as it may decrease the mean time between failure of some components. The cabinet
has ventilation openings to allow entry of cool air and escape of hot air. The cabinet provides
Page 8
© 2007, ADC Telecommunications, Inc.
Table 2. RAN Specifications
SPECIFICATION
-21 dBm
-41 dBm
-3 dB
-43 dB
-83 dB
10 usec
0 usec
0 usec
30 dB
-10 to +10 dB
0 to +30 dB
+/- 2dB
15 MHz block increments
15 MHz block increments
50 ohm
6.5 Watts (+38 dBm) composite
12.5 Watts (+41 dBm) composite
1 dB
COMMENT
Two tone tests at -56 dBm
RDC capability (at cabinet input)
A/D clip level, single RF channel
Selectivity
(function of SAW filter)
Selectivity
Selectivity
Activated if A/D clips, changes
gain of A/D and gain in digits.
Design ensures analog gain and
digital gain change will be timed
correctly. 15 dB noise figure at
-14 dB gain
Lower limit for simulcast with a
host tower site, the max reduces
effect of cascaded noise figure
Allows injection after BTS
amplifiers
Over temperature, frequency, and
aging valid for input signals
below AGC threshold
At antenna port
At antenna port
Configured at startup using fac-
tory calibration of modules and
user data

Advertisement

Table of Contents
loading

Table of Contents