Step 4 On the interface of the HyperTerminal, press Enter to display the user name prompt character.
Enter the user name and the password for registration according to the prompt (by default, the
user name is root and the password is admin) until the command line prompt character is
displayed. For the basic information on how to use the CLI, see CLI Operation Characteristics.
If the login fails, click
go to
parameter settings and the physical connection are normal, log in again.
To improve the system security, please modify your password after first login. You can run the terminal user
password command to modify your password.
Step 5 To configure the IP address of the ETH1 port, do as follows:
1.
2.
3.
4.
Step 6 To configure the IP address of the ETH0 port, do as follows:
1.
2.
3.
4.
5.
----End
Result
You can maintain and manage the device after logging in to the device through the serial port.

3.5.2 Login in Telnet Mode (Inband Management)

This topic describes how to log in to the UA5000 through the uplink port (inband management
port) in telnet mode to maintain and manage the UA5000.
Prerequisites
l
Issue 04 (2012-06-25)
NOTE
When the text is copied to the HyperTerminal, the Character delay parameter controls the speed at
which each character is sent. The Line delay parameter controls the interval between lines. If the
delay is too short, certain characters are omitted. If certain characters are omitted when the text is
copied to the HyperTerminal, modify the delay.
Step 1
to check the parameter settings or the physical connection are normal. If the
NOTE
In global config mode, run the interface eth command to enter the eth mode.
In ETH mode, run the ip address command to configure the IP address, the subnet mask
and the gateway of the ETH1 port.
Run the display ip address command to query the IP address and the subnet mask.
Run the sysman mode command to configure the network management mode.
Run the mac outband add command to add the MAC address of the outband management.
In global config mode, run the interface outband command to enter the outband mode.
In outband mode, run the ip address command to configure the IP address, the subnet mask
and the gateway of the ETH0 port.
Run the display ip address command to query the IP address, the subnet mask and the
gateway.
Run the sysman mode command to configure the network management mode.
You must log in to the UA5000 through the local serial port and the IP address and the
subnet mask must be configured for the UA5000. For detailed configuration, see
Login in the Local Serial Port
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
on the operation interface and then click
Mode.
3 Stand-Alone Commissioning
. If the login still fails,
3.5.1
32