UA5000 Universal Access Unit Product
V100R019
Commissioning Guide-PVM CLI
Issue
04
Date
2012-06-25
HUAWEI TECHNOLOGIES CO., LTD.

Advertisement

Table of Contents
loading

Summary of Contents for Huawei UA5000

  • Page 1 UA5000 Universal Access Unit Product V100R019 Commissioning Guide-PVM CLI Issue Date 2012-06-25 HUAWEI TECHNOLOGIES CO., LTD.
  • Page 2 All other trademarks and trade names mentioned in this document are the property of their respective holders. Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope.
  • Page 3: About This Document

    About This Document Intended Audience This document describes how to commission and verify the basic functions of the UA5000 from the aspects of hardware, software, interconnection, and maintenance and management. This ensures that the device runs stably and reliably on the network.
  • Page 4 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI About This Document Convention Description Italic Command arguments are in italics. Items (keywords or arguments) in square brackets [ ] are optional. { x | y | ... } Alternative items are grouped in braces and separated by vertical bars.
  • Page 5 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI About This Document Modified: 3.5.3 Login in Telnet Mode (Outband Management) 4.4 Commissioning the Interconnection Between the Device and the Router A.4.1 Setting the Default System Parameters A.4.2 Setting the Default Overseas Parameters...
  • Page 6: Table Of Contents

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI Contents Contents About This Document........................ii 1 Commissioning Description.......................1 1.1 Definition................................2 1.2 Commissioning Flow............................2 2 Commissioning Preparations......................4 2.1 Hardware Check..............................5 2.2 Software Requirements............................5 2.3 Tool Requirements.............................6 2.4 Data Requirements.............................7 3 Stand-Alone Commissioning......................9 3.1 Checking the Settings of Jumpers and DIP Switches..................11 3.1.1 Checking the Settings of DIP Switches and Jumpers of Environment Monitoring Boards....11...
  • Page 7 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI Contents 3.11 Detecting the Power on the Optical Port......................61 3.11.1 Detecting the Average Transmit Power of the Two-Fiber Bidirectional Optical Port......61 3.11.2 Detecting the Actual Input Power of the Two-Fiber Bidirectional Optical Port........65 3.11.3 Detecting the Average Transmit Optical Power of a Single-Fiber Bidirectional Optical Port.....69...
  • Page 8 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI Contents A.4.3 Setting the Default Parameters of the EMU..................125 A.5 Acronyms and Abbreviations........................126 Issue 04 (2012-06-25) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
  • Page 9: Commissioning Description

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 1 Commissioning Description Commissioning Description About This Chapter This topic describes the definition, prerequisites, and flow of the commissioning. 1.1 Definition Commissioning refers to the process of verifying the running of the device, the communication of the device with the NMS and other interconnected devices, and ensuring that the device can be used as required.
  • Page 10: Definition

    This flow is for the commissioning procedures in newly-created offices. For the existing offices, adjust the commissioning procedures and contents according to the actual situation. Prerequisites The hardware installation personnel must have installed and checked the UA5000 hardware. Flowchart This document describes how to commission the UA5000 in the following steps.
  • Page 11 Maintenance and Management Commissioning This topic describes how to verify the reliability of the device after commissioning the basic functions and services of the device to ensure the performance reliability of the UA5000. Issue 04 (2012-06-25) Huawei Proprietary and Confidential...
  • Page 12: Commissioning Preparations

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 2 Commissioning Preparations Commissioning Preparations About This Chapter This topic describes how to prepare hardware, software, tools, and data properly to ensure that the commissioning is implemented normally. 2.1 Hardware Check This topic describes how to check the hardware before the commissioning. Make sure that the hardware is available and check the hardware before the commissioning to facilitate the subsequent operations.
  • Page 13: Hardware Check

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 2 Commissioning Preparations 2.1 Hardware Check This topic describes how to check the hardware before the commissioning. Make sure that the hardware is available and check the hardware before the commissioning to facilitate the subsequent operations.
  • Page 14: Tool Requirements

    The commonly used commissioning tools are as tools follows: l HyperTerminal: Used for logging in to the UA5000 through the CLI. The tool is embedded in Windows. l TFTP and FTP: Used for loading software, which can be downloaded from http://support.huawei.com.
  • Page 15: Data Requirements

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 2 Commissioning Preparations Item Description Remarks Straight through cable Used for commissioning the services. Tail fiber Used for detecting the optical power and optical sensitivity, and transmitting the service upstream. Maintain (Generally) Portable computer with...
  • Page 16 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 2 Commissioning Preparations Item Description Networking and data It includes but is not limited to: plan l Network topology l IP address allocation l VLAN plan l Service type and data plan...
  • Page 17: Stand-Alone Commissioning

    3.5 Logging in to the System This topic describes how to log in to theUA5000 and then commission the UA5000 through the maintenance terminal. 3.6 Checking the Software Version This topic describes how to check whether the version of the running software meets the requirements for office deployment.
  • Page 18 3.12 Checking the Status of the Uplink Port This topic describes how to check the status of the uplink port to ensure that the interconnection between the UA5000 and the upper layer device is in the normal state, thus ensuring the normal communication.
  • Page 19: Checking The Settings Of Jumpers And Dip Switches

    (DIP) switches. This ensures that the settings conform to the actual application. Prerequisites The UA5000 must be disconnected from the power supply. Jumpers and DIP Switches of H303ESC The H303ESC board is located on the right side of the environment monitoring unit (EMU).
  • Page 20 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Jumper Settings Meanings Default Settings 2-3 connected The serial port SIO1 is RS-422. 1-2 connected The serial port SIO2 is 2-3 connected RS-232. 2-3 connected The serial port SIO2 is RS-422.
  • Page 21 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning DIP switch S7 is used to set the reporting mode and ratio. Table 3-4 provides the meanings and settings of S7. Table 3-4 Meanings and settings of the H303ESC S7...
  • Page 22 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Table 3-5 Meanings and settings of the H304ESC S4-S8 Jumper Settings Meanings Default Settings 1-2 connected The serial port SIO1 is 1-2 connected RS-232. 2-3 connected The serial port SIO1 is RS-422.
  • Page 23 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Table 3-7 Meanings and settings of the H304ESC S3 DIP Switch Settings Meanings Default Settings S3-1 The H304ESC board is used in the access network. The H304ESC board is used on the Local Exchange.
  • Page 24 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning The available dialing digits of the DIP switch S1 are 8. Table 3-8 provides the meanings and settings of S1. Table 3-8 Meanings and settings of the DIP switch S1...
  • Page 25: Checking The Dip Settings On The Monitoring Board Of The Fan

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Figure 3-4 Removing and inserting the ESC board Step 3 Hold the handlebar firmly on the front panel and pull out the ESC board from the PDU. Step 4 Check whether the settings of the jumpers and DIP switches on the ESC board are practical in application.
  • Page 26 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Figure 3-5 Layout of the DIP switches on the FCBA board H531FCBA SW101 SW102 OFF 1 2 3 4 Figure 3-6 shows the layout of the DIP switches on the H801FCBB board, and...
  • Page 27 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Table 3-9 Description of the DIP switches on the H801FCBB board Description Defaults SW2-1 Set the mapping sub-node addresses of data configuration. SW2-2 l ON corresponds to address bit 0.
  • Page 28 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Table 3-11 Relation between the DIP switch settings and the fan quantity SW2-6 SW2-5 Fan Quantity Table 3-12 provides the relation between the settings of the DIP switches and the speed adjustment mode of the fans.
  • Page 29: Powering On The Indoor Device

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Figure 3-8 Removing/Inserting the fan tray Step 2 Remove the fan tray from the service shelf, as shown in (2) of Figure 3-8. Step 3 Check whether the DIP switch settings on the fan monitoring and control board are consistent with the actual application.
  • Page 30: Powering On The Outdoor Device

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Procedure Step 1 Turn on the input power of the DC PDU. Step 2 Turn on the output control switches of the DC PDU. ----End Result The LED of the control board blinks 1s on and 1s off repeatedly.
  • Page 31: Commissioning The Power System

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning 3.4 Commissioning the Power System This topic describes how to commission the reliability of the power supply system so that the system can supply the power to the device in the normal state.
  • Page 32: Configuring The Battery And Checking The Power Supply Of The Battery

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Procedure Step 1 Remove a rectifier unit and check the power supply of the cabinet. Step 2 Insert the rectifier unit back into the cabinet. NOTE Repeat step 1 and step 2 to verify one by one whether other redundant rectifier units are normal.
  • Page 33: Checking The Power Supply Of The Power Board

    Step 6 In privilege mode, run the save command to save the related configuration. When the monitoring module and the UA5000 device communicate with each other in the normal state, the configured data take effect automatically. Step 7 Disconnect the mains supply, and check whether the cabinet power system can switch to the battery supply mode.
  • Page 34: Checking The Power Supply Of The Heat Exchanger

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Prerequisites The two configured PWX boards must work in the normal state. Precaution Wear the ESD wrist strap during the operation. When one PWX board is faulty, replace it in time. Ensure that the shelf does not work for long with only one power board.
  • Page 35: Logging In To The System

    After the power is restored, the alarm LED of the heat exchanger turns off, and the system recovers. 3.5 Logging in to the System This topic describes how to log in to theUA5000 and then commission the UA5000 through the maintenance terminal. 3.5.1 Login in the Local Serial Port Mode Generally, when you need to maintain, manage, and operate the device at the local end, you can log in to the system through the serial port.
  • Page 36 3 Stand-Alone Commissioning Flowchart Figure 3-10 shows the flowchart for logging in to the UA5000 in the local serial port mode Figure 3-10 Flowchart for logging into the UA5000 in the local serial port mode Procedure Step 1 Use a standard RS-232 serial port cable to connect the serial port on the PC to the COM port on...
  • Page 37 3 Stand-Alone Commissioning Select the serial port. Select the serial port on the PC, for example, COM2, that is connected to the UA5000, and then click OK, as shown in the following figure. Set the HyperTerminal communication parameters. For details, see the following figure.
  • Page 38 HyperTerminal is different from the baud rate of the serial port on the UA5000. In this case, you can modify the baud rate of the HyperTerminal and then log in to the system again. The system supports the following baud rates: 9600bit/s, 19200bit/s, 38400bit/s, 57600bit/s, and 115200bit/s.
  • Page 39 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Set the line delay and the character delay of the ASCII code. Click ASCII Setup. In the dialog box that is displayed, set Line delay to 200 and Character delay to 200, and then click OK, as shown in the following figure. By default, Line delay is set to 0 and Character delay to 0.
  • Page 40: Login In Telnet Mode (Inband Management)

    UA5000. Prerequisites You must log in to the UA5000 through the local serial port and the IP address and the subnet mask must be configured for the UA5000. For detailed configuration, see 3.5.1...
  • Page 41 IP address for the maintenance terminal, see Configuring the IP Address of the Maintenance Terminal. NOTE In the following operations, the configuration of the UA5000 must be performed through the local serial port. Networking — LAN Figure 3-11 shows the example network for inband management through telnet in a LAN.
  • Page 42 Log in to the system Procedure Step 1 Set up the configuration environment. l If you log in to the UA5000 in the LAN inband management mode through telnet, set up a network environment according to the networking shown in Figure 3-11.
  • Page 43: Login In Telnet Mode (Outband Management)

    UA5000. Prerequisites You must log in to the UA5000 through the local serial port and the IP address and the subnet mask must be configured for the UA5000. For detailed configuration, see 3.5.1...
  • Page 44 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Networking — LAN Figure 3-15 shows the example network for configuring the Networking through the outband management port over a LAN in telnet mode. Figure 3-15 Example network for outband management over a LAN in telnet mode...
  • Page 45 Log in to the system Procedure Step 1 Set up the configuration environment. l If you log in to the UA5000 in the LAN outband management mode through telnet, set up a network environment according to the networking shown in Figure 3-15.
  • Page 46: Login In Ssh Mode (Inband Management)

    3.5.4 Login in SSH Mode (Inband Management) This topic describes how to log in to the UA5000 in secure shell (SSH) mode through the uplink port (inband management port) and then maintain and manage the UA5000. In SSH mode, the authentication, encryption, and authorization are provided to ensure the security of network communications.
  • Page 47 Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Prerequisites You must log in to the UA5000 through the local serial port and the IP address and the subnet mask must be configured for the UA5000. For detailed configuration, see 3.5.1 Login in the Local Serial Port Mode.
  • Page 48 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Figure 3-20 Example network for configuring the inband management over a WAN in SSH mode Router ETH0 0/4/0 ETH1 UA5000 PVMB Data Plan — SSH Mode Table 3-14 provides the data plan for configuring the inband management over a LAN or WAN in SSH mode.
  • Page 49 Procedure Step 1 Set up the configuration environment. l If you log in to the UA5000 through the inband management over a LAN in SSH mode, set up a network environment according to the networking shown in Figure 3-19.
  • Page 50 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning l If you log in to the UA5000 through the inband management over a WAN in SSH mode, set up a network environment according to the networking shown in Figure 3-20.
  • Page 51 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning l all: The password or RSA key is used for authentication. It indicates that an SSH user can log in to the device after the user has passed the password or RSA authentication.
  • Page 52 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Figure 3-23 Interface of the key generator After generating the key, click Save public key and Save private key to save the public key and the private key.Figure 3-24 shows the interface of saving the public key and the private key.
  • Page 53 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Figure 3-24 Interface of saving the public key and the private key Generate the RSA public key. Start sshkey.exe, the password convertor on the client, click Browse, select the public key file that is saved, and then click Convert to convert the client public key to the RSA public key.Figure 3-25...
  • Page 54 Step 8 Assign the public key to the SSH user. Run the ssh user assign rsa-key command to assign the public key to user huawei. huawei(config)#ssh user huawei assign rsa-key key Step 9 Log in to the system.
  • Page 55 Figure 3-26 Interface of the SSH client software Log in to the system. Choose Session from the navigation tree, and then enter the IP address of the UA5000 in the Host Name (or IP address) text box, as shown in Figure 3-27.
  • Page 56: Login In Ssh Mode (Outband Management)

    CLI, see CLI Operation Characteristics. 3.5.5 Login in SSH Mode (Outband Management) This topic describes how to log in to the UA5000 in secure shell (SSH) mode through the maintenance network port (outband management port) and then maintain and manage the UA5000.
  • Page 57 Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Prerequisites You must log in to the UA5000 through the local serial port and the IP address and the subnet mask must be configured for the UA5000. For detailed configuration, see 3.5.1 Login in the Local Serial Port Mode.
  • Page 58 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Data Plan — SSH Mode Table 3-15 provides the data plan for configuring the outband management over a LAN or WAN in SSH mode. Table 3-15 Data plan for configuring the outband management over a LAN or WAN in SSH...
  • Page 59 Procedure Step 1 Set up the configuration environment. l If you log in to the UA5000 through the outband management over a LAN in SSH mode, set up a network environment according to the networking shown in Figure 3-29.
  • Page 60 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning l If you log in to the UA5000 through the outband management over a WAN in SSH mode, set up a network environment according to the networking shown in Figure 3-30.
  • Page 61 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning l rsa: The RSA public key is used for authentication. l all: The password or RSA key is used for authentication. It indicates that an SSH user can log in to the device after the user has passed the password or RSA authentication.
  • Page 62 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Figure 3-33 Interface of the key generator After generating the key, click Save public key and Save private key to save the public key and the private key.Figure 3-34 shows the interface of saving the public key and the private key.
  • Page 63 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Figure 3-34 Interface of saving the public key and the private key Generate the RSA public key. Start sshkey.exe, the password convertor on the client, click Browse, select the public key file that is saved, and then click Convert to convert the client public key to the RSA public key.Figure 3-35...
  • Page 64 Step 8 Assign the public key to the SSH user. Run the ssh user assign rsa-key command to assign the public key to user huawei. huawei(config)#ssh user huawei assign rsa-key key Step 9 Log in to the system.
  • Page 65 Figure 3-36 Interface of the SSH client software Log in to the system. Choose Session from the navigation tree, and then enter the IP address of the UA5000 in the Host Name (or IP address) text box, as shown in Figure 3-37.
  • Page 66: Checking The Software Version

    Figure 3-38 Interface of logging in to the system through the SSH client software ----End Result After logging to the system, you can maintain and manage the UA5000. For the basic information on how to use the CLI, see CLI Operation Characteristics. 3.6 Checking the Software Version This topic describes how to check whether the version of the running software meets the requirements for office deployment.
  • Page 67: Adding A Shelf

    NOTE When adding a master shelf, the UA5000 adds the active/standby boards automatically. To prevent data inconsistency, the standby control board will be reset when adding a master shelf, which is in the normal state.
  • Page 68: Configuring The Board

    The script file must be available. For the information on how to make a script, see Making a Script. The hardware must be installed and checked. The commissioning terminal must log in to the UA5000 successfully. Precaution Each command in the script file must end with an Enter character. Procedure Step 1 Open the script file and copy the commands in the file into the maintenance command line interface (CLI).
  • Page 69: Configuring The Networking Mode Of The System

    Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning 3.10 Configuring the Networking Mode of the System When the networking modes of the UA5000 are different, perform the operation to configure the networking mode of the system to independent networking or integrated access networking. Precaution The system networking mode that is configured must be consistent with the actual networking mode.
  • Page 70 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Precautions DANGER Do not look into the Tx laser port and the fiber connector on the optical interface board without eye protection. Use the unit dBm of the optical power meter for the detection.
  • Page 71 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Step 4 Repeat the preceding steps three times, and then check whether the detected value of the optical power meets technical requirements (determined by the specifications of different optical modules).
  • Page 72 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Parameter Specification Interface mode Single mode Transmission distance (km) Operating wavelength (nm) 1550 1550 Mean transmit power (dBm) -5 to 0 -3 to +2 Extinction ratio (dB) Receiver sensitivity (dBm) <...
  • Page 73: Detecting The Actual Input Power Of The Two-Fiber Bidirectional Optical Port

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Parameter Specification Interface mode Multi-mode Transmission distance (m) Mean transmit power (dBm) -9.5 to -4 Central wavelength (nm) Extinction ratio (dB) Receiver sensitivity (dBm) < -17 Receiver overload power (dBm) Standards compliance IEEE 802.3z...
  • Page 74 Step 2 Set the detecting wavelength of the optical power meter based on the working wavelength of the detected port. Step 3 On the UA5000, configure a channel from an uplink port to the detected port. Step 4 Increase the optical attenuation gradually. When a small number of packets are lost, decrease the optical attenuation gradually until no packet is lost in a short period (method: ping the peer device on the UA5000 to check the packet loss condition).
  • Page 75 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Table 3-20 Technical specifications of the 1000base-Lx port Parameter Specification Transmission rate 1000 Mbit/s Interface type Interface mode Single mode Transmission distance (km) Central wavelength (nm) 1310 Mean transmit power (dBm)
  • Page 76 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Table 3-22 Technical specifications of the 100Base-Fx port Parameter Specification Transmission rate 100 Mbit/s Interface type Lucent connector (LC) Interface mode Multi-mode Single mode Single mode Transmission distance (km)
  • Page 77: Detecting The Average Transmit Optical Power Of A Single-Fiber Bidirectional Optical Port

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning 3.11.3 Detecting the Average Transmit Optical Power of a Single- Fiber Bidirectional Optical Port This topic describes how to detect the average transmit power of a single-fiber bidirectional optical port from the local end to ensure that the average transmit optical power of the optical port is in the normal state.
  • Page 78 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Figure 3-41 Detecting the transmit optical power of a single-fiber bidirectional optical port Detected port Optical port 接口板/主控板 UA5000 Optical power meter NOTE Select the proper patch codes with different splices because the optical power meter may have different interfaces.
  • Page 79 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Table 3-24 Technical specifications of the 1000base-Lx port Parameter Specification Transmission rate 1000 Mbit/s Interface type Interface mode Single mode Transmission distance (km) Central wavelength (nm) 1310 Mean transmit power (dBm)
  • Page 80 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Table 3-26 Technical specifications of the 100Base-Fx port Parameter Specification Transmission rate 100 Mbit/s Interface type Lucent connector (LC) Interface mode Multi-mode Single mode Single mode Transmission distance (km)
  • Page 81: Detecting The Actual Input Power Of A Single-Fiber Bidirectional Optical Port

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Table 3-28 Specifications of the GPON port Parameter Description Transmission rate Receive: 1.25 Gbit/s Transmit: 2.5 Gbit/s Interface type SC/PC Maximum transmission distance 20 km Standards compliance ITUT G984.2 CLASS B+...
  • Page 82 Step 2 Set the detecting wavelength of the optical power meter based on the working wavelength of the detected port. Step 3 On the UA5000, configure the channel from an uplink port to the detected port. Step 4 Increase the value of the optical attenuation gradually. When a small number of packets are lost, decrease the value of the optical attenuation gradually.
  • Page 83 Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning until no packets are lost in a short period (you can ping the peer device on the UA5000 to check the packet loss). Note that the adjusting process should be performed stably and slowly.
  • Page 84 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Parameter Specification Interface type Interface mode Single mode Transmission distance (km) Operating wavelength (nm) 1550 1550 Mean transmit power (dBm) -5 to 0 -3 to +2 Extinction ratio (dB) Receiver sensitivity (dBm) <...
  • Page 85 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Parameter Specification Interface type Interface mode Multi-mode Transmission distance (m) Mean transmit power (dBm) -9.5 to -4 Central wavelength (nm) Extinction ratio (dB) Receiver sensitivity (dBm) < -17 Receiver overload power (dBm) Standards compliance IEEE 802.3z...
  • Page 86: Checking The Status Of The Uplink Port

    3.12 Checking the Status of the Uplink Port This topic describes how to check the status of the uplink port to ensure that the interconnection between the UA5000 and the upper layer device is in the normal state, thus ensuring the normal communication.
  • Page 87: Changing The System Name

    This topic describes how to add system operation users and modify the attributes of the system operation users. 3.14.1 Adding a System User When accessing and configuring the UA5000, you need to add the system users with different attributes to facilitate management. Prerequisites You must have the administrator right or higher right.
  • Page 88 Users are classified into three levels: common user, operator, and administrator. NOTE The assigned operation rights are different. Therefore, UA5000 divides the user operation rights into the following levels: common user, operator, administrator, and super user. The users of each level can add only lower-level users. The user operation rights are as follows.
  • Page 89: Modifying The System User Attributes

    The queried user information is the same as the actual data plan. Example Example: Under the administrator level, to add a system user with the account of huawei, password of test01, and level of common user, permitted reenter number of 3, and appended...
  • Page 90 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Context Table 3-37 lists the user attributes that can be modified and the related restrictions. Table 3-37 Modifying the user attributes User Attribute Description Password l The super user and the administrator can change their own passwords and the passwords of users at lower levels.
  • Page 91 UA5000 by using the original user name and password is successful. Example To modify the attributes of user huawei, password to test02, bound profile to operator, right to operator, permitted reenter number to 4, and appended information to operator, do as follows: huawei(config)#terminal user password User Name(<=15 chars):huawei...
  • Page 92: Checking The System Time

    3.15 Checking the System Time This topic describes how to check whether the system time, time zone, time stamp, and start and end Daylight Saving Time (DST) of the UA5000 are consistent with the actual conditions. Procedure Step 1 Check the system time.
  • Page 93: Commissioning The Emu

    3 Stand-Alone Commissioning 3.16 Commissioning the EMU The UA5000 provides the function of monitoring various environment parameters (such as the temperature, humidity, and power voltage) so that the device runs in the stable environment. This topic describes how to commission the environment monitoring unit (EMU).
  • Page 94: Commissioning The Fan Emu

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Item Data Analog parameters ESC analog ID: 0 (name: temperature) Upper threshold of the temperature alarm: 55 Lower threshold of the temperature alarm: 5 Digital parameters ESC digital ID: 1 (name: door status sensor 0)
  • Page 95 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning The HABD shelf supports the configuration of the fan tray through software. The fan tray can be added to the H602HABD, H612HABL, and H601HABM shelves and can run in the normal state.
  • Page 96: Checking The Auto-Save Settings

    The system must work in the normal state. Precaution The UA5000 supports the auto-save function in two modes. One is that the data is saved according to the specified interval (autosave interval) and the other is that the data is saved at the specified time point (autosave time).
  • Page 97: Saving The Data

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Over-frequent data saving affects the system performance. The recommended saving interval is 60 minutes or longer. Run the save command to save the configuration data no matter whether the auto-save function is enabled.
  • Page 98: Backing Up The System File

    The commissioning terminal must be installed with the TFTP software. Precaution The UA5000 supports multiple types of backplanes. The backup databases of different control boards that match different backplanes can not be interoperable, otherwise the data will be in chaos.
  • Page 99 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Figure 3-43 Running the TFTP application If the default path is not the path where the loaded file is saved, select Setting to set the file path, as shown in Figure 3-44.
  • Page 100 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 3 Stand-Alone Commissioning Click OK after the settings. Step 2 In privilege mode, run the backup data command in TETP mode to back up the files. When running the backup command, enter the following information: l Name of the backup file.
  • Page 101: Commissioning The Interconnection

    This topic describes how to commission the MG interface. The MG interface is an interface for the communication between the UA5000 and the MGC. This interface can use the H.248 or MGCP protocol. Before commissioning the service, you must commission the MG interface successfully.
  • Page 102: Nms Interconnection Commissioning

    (iManager U2000) as an example. 4.1.1 Commissioning the Outband NMS This topic describes how to verify that the UA5000 can support the outband NMS through the local maintenance network port (the outband NMS interface), so that the iManager U2000 can maintain the device through this management channel.
  • Page 103 SET community private name Procedure Configure the outband NMS on the UA5000 side. Configure the MAC address of the outband NMS network port. huawei(config)#mac outband add 02-E0-FC-02-02-03 active Query the MAC address pool. huawei(config)#display mac active Issue 04 (2012-06-25) Huawei Proprietary and Confidential Copyright ©...
  • Page 104: Commissioning The Inband Nms

    Configure the route gateway to network section 10.20.1.0/24 as 10.10.1.10. NOTE When the IP address of the UA5000 outband NMS interface is not in the same subnet as the IP address of the iManager U2000, you need to configure the route information to forward the NMS packet.
  • Page 105 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 4 Commissioning the Interconnection Figure 4-2 Networking for the inband NMS iManager U2000 Router PVMB ETH0 ETH1 UA5000 NOTE In the integrated upstream mode, the iManager U2000 connects to the internal network port of the PVMB/ PVMD control board through the IP network, and manages the device through the upstream network port of the IPMB/IPMD control board.
  • Page 106 When the IP address of the inband NMS interface is not in the same subnet of the iManager U2000, you need to configure the route for forwarding the IP packets. ----End Result You can maintain and manage the UA5000 through the iManager U2000. Issue 04 (2012-06-25) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
  • Page 107: Commissioning The Mg Interface

    This topic describes how to commission the MG interface. The MG interface is an interface for the communication between the UA5000 and the MGC. This interface can use the H.248 or MGCP protocol. Before commissioning the service, you must commission the MG interface successfully.
  • Page 108 4 Commissioning the Interconnection NOTE The UA5000 supports the independent upstream transmission and the integrated upstream transmission modes. This commissioning task uses the independent upstream transmission mode. To use the integrated upstream transmission mode, run the working mode command to set the working mode of the PVMB board as the integrated upstream transmission mode.
  • Page 109: Commissioning The Mg Interface Connection (Through Mgcp)

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 4 Commissioning the Interconnection huawei(config-if-h248-0)#if-h248 attribute mgip 10.10.10.2 mgport 2944 code text transfer udp domainName ua5000.com primary-mgc-ip1 10.10.20.1 primary-mgc-port 2944 mg-media-ip1 10.71.46.69 Step 3 Restart the MG interface. huawei(config-if-h248-0)#reset coldstart Command: reset coldstart...
  • Page 110 10.10.10.2/24 NOTE The UA5000 supports the independent upstream mode and the integrated upstream mode. In the commissioning task, the independent upstream mode is used. In the case of the integrated upstream mode, you need to run the working mode command to set the working mode of the PVMB to integrated upstream mode.
  • Page 111: Commissioning The Interconnection With The Sip Interface

    4.3 Commissioning the Interconnection with the SIP Interface This topic describes how the UA5000 as the voice over IP gateway (VGW) communicates with the IMS through the SIP interface. Prerequisites The voice protocol supported by the system must be configured to SIP.
  • Page 112 UA5000 NOTE The UA5000 supports the independent upstream mode and the integrated upstream mode. The commissioning task uses the independent upstream mode. If the integrated upstream mode is used, you need to run the working mode command to set the working mode of the PVMD board to integrated upstream mode.
  • Page 113 10.13.4.116 signal-ip 10.13.4.116 signal-port 5555 transfer udp primary-proxy-ip1 10.13.4.110 primary- proxy-port 5555 secondary-proxy-ip1 10.13.4.120 secondary-proxy-port 5555 home-domain UA5000.com sipprofile-index 1 Step 3 Configure the optional attributes of the SIP interface. huawei(config-if-sip-0)#if-sip attribute optional mg-domain huawei.com phone- context +86755 Step 4 Query the configured attributes of the SIP interface.
  • Page 114: Commissioning The Interconnection Between The Device And The Router

    4.4 Commissioning the Interconnection Between the Device and the Router This topic describes how to check whether the UA5000 can normally communicate with the router and whether the UA5000 can access the upper-layer device through the router. Service Requirements...
  • Page 115 Step 2 Save the data. huawei(config)#save ----End Result After the UA5000 is interconnected with the router successfully, you can ping IP address 10.10.1.0/24 from the UA5000. Issue 04 (2012-06-25) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.
  • Page 116: Maintenance And Management Commissioning

    5.1 Checking the Alarm Function and the Event Function This topic describes how to check whether the alarm function and the event function of the UA5000 are in the normal state after all the alarms and events are output to the command lines. 5.2 Checking the Log This topic describes how to check the log through the commissioning terminal.
  • Page 117: Checking The Alarm Function And The Event Function

    This topic describes how to check whether the alarm function and the event function of the UA5000 are in the normal state after all the alarms and events are output to the command lines. 5.1.1 Verifying the Alarm Function and the Event Function This topic describes how to check whether the alarm function and the event function of the device are in the normal state by triggering various alarms or events through related operations.
  • Page 118 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 5 Maintenance and Management Commissioning Operation Description Set the upper temperature limit of the Check whether the alarm/event attributes including EMU to a value lower than the ambient the alarm/event severity and the alarm/event temperature.
  • Page 119: Querying Alarms And Events

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 5 Maintenance and Management Commissioning Operation Description Discharge the battery to the under- Check whether the alarm/event attributes including voltage value. the alarm/event severity and the alarm/event occurrence time are correct and check whether the alarm/event on the NMS is consistent with the alarm/event on the maintenance terminal.
  • Page 120: Checking The Log

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 5 Maintenance and Management Commissioning Table 5-3 Commands for querying history events To… Use… Query events by event display event history eventsn sn [ detail | list ] serial number Query events by event...
  • Page 121 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI 5 Maintenance and Management Commissioning Step 2 In the common user mode, run the display log command to query the records in the log. ----End Result The log records the operation information.
  • Page 122: A Additional Information

    A.1 Configuring the IP Address of the Maintenance Terminal This topic describes how to configure the IP address of the maintenance terminal so that the maintenance terminal can access the UA5000 normally in telnet mode or SSH mode. A.2 Making a Script This topic describes how to make a script according to the collected data plan.
  • Page 123: Configuring The Ip Address Of The Maintenance Terminal

    A.1 Configuring the IP Address of the Maintenance Terminal This topic describes how to configure the IP address of the maintenance terminal so that the maintenance terminal can access the UA5000 normally in telnet mode or SSH mode. Prerequisite The maintenance terminal must be connected and started.
  • Page 124: Making A Script

    Table A-1 provides the data plan for configuring the example script. After the example script is configured, the maintenance terminal in the management center can log in to the UA5000 to commission the basic functions of the device. Table A-1 Script data plan...
  • Page 125: Operation Guide On Battery Supplementary Charge

    Stand-alone digitap: 1234xxxx l Escape bucket digitmap: 110|119|999 IP address l Media IP address of MG interface 0 of the UA5000: 10.10.10.2/24 l Signaling IP address of MG interface 0 of the UA5000: 10.10.10.4/24 l IP address of the MGC: 10.10.20.1/24 The following displays the commands that need to be included in the script according to the preceding data plan.
  • Page 126: Preparing Tools

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI A Additional Information A.3.1 Preparing Tools Before performing the supplementary charge for the battery, check and ensure that the tools that facilitate the subsequent commissioning work are available. Table 1 lists the check items for tools before the commissioning.
  • Page 127: Operation Process

    UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI A Additional Information Do not connect the positive and negative polarities of the battery reversely. During the test, ensure that all the cables are connected reliably and tightly. Otherwise, the circuit may catch fire or be overheated after the circuit is closed, which may burn the battery and cause accidents when the problem reaches a serious extent.
  • Page 128: Software Package Settings

    ----End A.4 Software Package Settings This topic describes the software package settings of the UA5000. A.4.1 Setting the Default System Parameters The default system parameter settings of the UA5000 are as follows: Table A-3 System parameters Parameter Meaning Default Setting Index Howler tone sending identifier.
  • Page 129: Setting The Default Overseas Parameters

    Power line alarm switch. 0: not support; 1: support 0: not support Long-time call alarm duration. Multiple of 30 minutes. 0 min A.4.2 Setting the Default Overseas Parameters The default overseas parameter settings of the UA5000 are as follows: Table A-4 Overseas parameters Parameter Meaning...
  • Page 130 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI A Additional Information Parameter Meaning Default Setting Index Flag of whether AN using the resource unavailable unit 0: not use or not. 0: not use; 1: use (Brazil standard) Flag of AN sending LE off-hook signal or not in case 0: not send of call conflict.
  • Page 131 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI A Additional Information Parameter Meaning Default Setting Index Hotline ringing parameters (0~255). For configuring this parameter, refer to the initial and cadence ringing types of the V5 interface. Length of timer for line card send on-hook message 1000 ms after howler tone (ms).
  • Page 132 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI A Additional Information Parameter Meaning Default Setting Index Flag of whether using user-defined ring 15 as default 65535 ring or not and flag of whether enable the optimization of CC0SASL board name or not.
  • Page 133 Reserved parameters 65535 A.4.3 Setting the Default Parameters of the EMU Table A-5 Table A-6 provide the parameter settings of the EMU on the UA5000. Table A-5 Default parameter settings of the H303ESC and H304ESC Parameter Default Setting Sub-node Analog parameters ESC analog parameter IDs l 0: allocated to the temperature sensor by default (read-only).
  • Page 134 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI A Additional Information Parameter Default Setting Definition of user-defined alarm indexes 1: AC voltage; 2: AC switch; 3: battery voltage; 4: battery fuse; 5: load fuse; 6: rectifier module; 7: secondary power supply; 8: door status of the cabinet;...
  • Page 135 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI A Additional Information Direct Current Digital Subscriber Line Board Digital Signal Processor DTMF Dual-Tone Multifrequency Environment Monitor Unit EPON Ethernet Passive Optical Network Environment Supervision Control Frequently asked question Fast Ethernet FoIP...
  • Page 136 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI A Additional Information Media Gateway Controller MGCP Media Gateway Control Protocol MoIP Modem over IP Optical Line Terminal Optical Network Unit Private Branch Exchange Pulse Code Modulation POTS Plain Old Telephone Service...
  • Page 137 UA5000 Universal Access Unit Product Commissioning Guide-PVM CLI A Additional Information User Datagram Protocol Virtual Access Gateway VLAN Virtual Local Area Network VoIP Voice over IP xDSL x Digital Subscriber Line Issue 04 (2012-06-25) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd.

Table of Contents