VII. OPERATING THE BLAST CHILL CONTROL - SET UP USERS
MAIN MENU
AIR 35
BY TEMP
BY PROD
BY TIME
08:05:01
MORE
MAIN MENU
AIR 35
BY TEMP
BY PROD
BY TIME
08:05:01
MORE
MAIN MENU
08:06:01
HOLD PROD
PRINT
DEFROST
SETUP
BACK
SETUP
09:04:11
PRODUCTS
SYS PAR
USERS
MAIN MENU
SETUP USERS:
ADD
DELETE ALL
EDIT/DELETE
B A C K
SELECT
SUPERVISOR:
↓ ↓ ↓ ↓ ↓ TIM SMITH
↓ ↓ ↓ ↓ ↓ PASSWORD (PIN): 07↑ ↑ ↑ ↑ ↑
CANCEL
ENTER
ENTER NAME:
↓ ↓ ↓ ↓ ↓ _
BACK
NEXT
CANCEL
ENTER
ENTER NAME:
↓ ↓ ↓ ↓ ↓ TIM SMITH
BACK
NEXT
CANCEL
ENTER
SETUP USER:
SECURITY LEVEL:0PER
↓ ↓ ↓ ↓ ↓ PASSWORD (PIN): 00↑ ↑ ↑ ↑ ↑
ENTER
SETUP USER:
SECURITY LEVEL:0PER
↓ ↓ ↓ ↓ ↓ PASSWORD (PIN): 23↑ ↑ ↑ ↑ ↑
ENTER
SETUP USER:
SECURITY LEVEL:0PER
↓ ↓ ↓ ↓ ↓ PASSWORD (PIN): 23↑ ↑ ↑ ↑ ↑
ENTER
VII. h - SET-UP USERS:
°
F
The SmartChill
have their own unique BY PRODUCT and SYSPAR settings already
programmed, facilitating the changing chilling needs of different production
shifts. To add new user settings please follow the below procedure.
°
F
STEP ONE:
STEP TWO:
STEP THREE: Press the button to the left of where USERS is shown on the
STEP FOUR: Press the button to the left of where ADD is shown on the
↑ ↑ ↑ ↑ ↑
STEP FIVE:
↑ ↑ ↑ ↑ ↑
↑ ↑ ↑ ↑ ↑
STEP SIX:
STEP SEVEN: To enter the new use's two-digit PASSWORD, press the buttons
control offers the convenience of having individual operators
®
From the MAIN MENU, select MORE by pressing the button to
the right of where this is shown on the display. The menu
shown will then change to display additional menu options.
Press the button to the right of where SETUP is shown on the
display. Note when you first enter SETUP, only Preset Supervisor
is available. On the PASSWORD (PIN) line, use the UP or DOWN
keys until 57 is displayed as the Preset Supervisor's Personal
Identification Number. Press ENTER. The menu shown will
then change back to display the SETUP menu options.
If users have already been setup, select the supervisor's name
using the UP or DOWN keys. On the next line, use the UP or
DOWN keys to enter their Password (or Personal Identification
Number). Press ENTER. The menu shown will then change
back to display the SETUP menu options.
display.
display to add new users to the roster.
NOTE: The first user entered is automatically given Supervisor
access. This can be changed by using the EDIT/DELETE
selection to change a given user's security level or PIN number,
or delete an entire user from the roster. DELETE ALL removes
all users from the roster.
To enter the name of a new user, press the buttons to the left
and right of the UP and DOWN arrows to scroll through the
alphabet, one character at a time. Press the button to the right
of where NEXT is shown on the display to set this character and
move on to the next letter, repeating this until the new users
name is complete.
NOTE: BACK moves the cursor one space to the left to allow for
editing. Press the button to the right of where ENTER is shown
on the display to save the new users name (CANCEL aborts this
process).
Select the new users security level by pressing the button to
the right of where SECURITY LEVEL is shown on the display
(pressing this button toggles between OPER (operator level)
and SUPV (supervisor). Please note that at least one user must
already be set-up as a supervisor before an operator access
level can be selected.
to the left and right of the UP and DOWN arrows to scroll
through the numbers 00-99. Press the button to the right of
where ENTER is shown on the display to set this users
access level and pin number. The display will return to the SET-
UP USERS menu. Press the button to the right of where BACK
is shown on the display to return to the SETUP menu. Press the
button to the left of where MAIN is shown on the display to
return to the main menu.
-19-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rbc200rtRbc400Rbc400rtRbc50Rbc100

Table of Contents