Traulsen R Series Owner's Manual
Hide thumbs Also See for R Series:

Advertisement

OWNER'S MANUAL
Instructions for the installation, operation
and maintenance of all Traulsen:
R & A Se rie s Re ach-In & Rol l- I n Re f r i ge ra t or s*
R & A Se rie s Pas s-Thru & Rol l -Th r u R ef ri ger at or s*
R & A Se rie s Re ach-In & Rol l- I n F r eez er s*
R & A Se rie s Re ach-In Refr i ger at or / F r eez er s*
R & A Se rie s Re ach-In & Rol l- I n Ho t Fo od Ca bi n et s*
R & A Se rie s Pas s-Thru & Rol l -Th r u H ot Foo d C ab i net s*
*Please Note: This manual is intended for use with the above referenced equipment manufactured after April 01, 2019. To obtain a copy of the correct Owner's Manual to support
the same products manufactured prior to this date, please contact Traulsen Service at (800) 825-8220.
4401 Blue Mound Road Fort Worth, Texas 76106 (USA)
Phone: 800.825.8220 | Service Fax: 817.740.6757 | E-mail: service@traulsen.com | Website: traulsen.com
Form Number: TR35743 | Part Number: 375-60176-00 | Revision Date: 11-16-20
Hours of Operation: Monday - Friday 7:30 a.m. - 4:30 p.m. (CST)

Advertisement

Table of Contents
loading

Summary of Contents for Traulsen R Series

  • Page 1 *Please Note: This manual is intended for use with the above referenced equipment manufactured after April 01, 2019. To obtain a copy of the correct Owner’s Manual to support the same products manufactured prior to this date, please contact Traulsen Service at (800) 825-8220.
  • Page 2: The Serial Tag

    The serial tag is a permanently affixed label on which is recorded Ft. Worth, TX 76106 800-825-8220 vital electrical and refrigeration data about your Traulsen product, as well as the model and serial number. This tag is located in the MODEL:...
  • Page 3: Receipt Inspection

    The door(s) must be able to open a minimum of 90° in order to make use of the maximum clear door width available. III. b - PACKAGING All Traulsen units are shipped from the factory bolted to a Fig. 1 sturdy wooden pallet and packaged in a durable cardboard container.
  • Page 4: E - Roll-In Model Installation

    After installing the ramp(s), it too should be sealed Please note that Traulsen units are not designed to be moved to the floor. while on legs. If the unit requires moving, a pallet jack or forklift should be used to prevent damage.
  • Page 5: H - Remote Installation

    III. INSTALLATION (continued) III. f - III. g - INSTALLING THE CONDENSATE EVAPORATOR ATTACHING DOUBLE DEPTH UNITS TOGETHER (cont) (cont’d) 6. Screw the drain extension into the “U-Trap”. Next, using two pipe clamps, pull the units together (see figure 5). Install the covers over the gap formed between the units From inside the cabinets, using the screws provided, install the breaker strips using the strip as a template.
  • Page 6: Operation

    Refer to the wiring diagram for any service work performed and starts at 32°F. The total refrigeration system operation on the unit. Should you require one, please contact Traulsen is then resumed. Service at (800) 825-8220, and provide the model and serial number of the unit involved.
  • Page 7: Care And Maintenance

    The most important thing you can do to insure a long, every 6 months or when the finless condenser coil presents reliable service life for your Traulsen is to regularly clean a certain level of obstruction of significant dirt on the tubing.
  • Page 8 V. f - REPLACING THE LIGHT BULB All Traulsen R & A Series models are supplied with LED lighting with the exception of heated units. Optional tube style display lighting is available (except for sliding glass door models for which fluorescent lights are supplied standard).
  • Page 9 IMPORTANT NOTE: While accessing the Controller Menu, two line, small font text messages will be displayed. In Your new Traulsen Refrigerator, Freezer or Hot Food cabinet this document two line messages are denoted as follows, is equipped with a state-of-the-art electronic control, which “TopLine, BottomLine”.
  • Page 10 VI. CONTROL BASICS (continued) VI. e - ACCESS POWER FAILURE DATA VI. c - INITIATE A DEFROST All Traulsen units are setup to defrost automatically. If 1. While the cabinet temperature is displayed (home necessary, the user may manually initiate a defrost: screen), press the Enter/Modify Key(↵).
  • Page 11 VI. CONTROL BASICS (continued) VI. g - CHANGE FAHRENHEIT (°F) TO CELSIUS (°C) 1. While the cabinet temperature is displayed (home screen), press the Enter/Modify Key(↵). “SubMenu 1/5, Sensor Readings” will display. 2. Push the Plus(+) or Minus(-) Key to navigate the submenu system until, “SubMenu 2/5, Settings”...
  • Page 12 VI. CONTROL BASICS (continued) VI. h - PARAMETER QUICK REFERENCE CHART PARAMETER SUBMENU PASSWORD DATA TempCab Sensor Readings Cabinet Temperature TempEvap Sensor Readings Evaporator Coil Temperature TempLiqLine Sensor Readings Liquid Line Temperature TempCabSp Settings Temperature Setpoint TempCabSPDiff Settings Cabinet Temperature Differential CabFanMode Settings Fan Mode...
  • Page 13: Troubleshooting

    VII. TROUBLESHOOTING VII. a -TROUBLESHOOTING GUIDE FIND YOUR PROBLEM HERE REMEDY a. Check if cord & plug has been disconnected. 1. Condensing unit fails to start. b. Check control temperature setting. a. Are doors closing properly? 2. Condensing unit operates for prolonged periods or b.
  • Page 14: Stainless Steel Overview

    If unsure, its probably best to just Special care should be taken to position your unit properly assume that it does and avoid its use in cleaning a Traulsen to prevent accidental dents and scratches. refrigeration product.
  • Page 15 Care must be taken to rub this on the area of help retain the appearance of your Traulsen refrigeration rust only in the direction of the stainless steel’s grain.
  • Page 16: Service And Warranty

    Traulsen reserves the right to change specifications or discontinue models without notice. IV. b - SERVICE SUPPORT INFORMATION To purchase replacement parts or to speak to service support for Traulsen units please contact our Ft. Worth facility by phone at 800-825-8220 or fax to 817-740-6748 (parts) or 817-740-6757 (service).
  • Page 17 Purchaser. In the case of a nonconforming part, Purchaser must return the part to Traulsen within 30 days from the date of repair. Failure to return a claimed defective part to Traulsen within the 30 days will waive the right to the warranty claim.
  • Page 18 4401 Blue Mound Road Fort Worth, Texas 76106 (USA) Phone: 800.825.8220 | Service Fax: 817.740.6757 | E-mail: service@traulsen.com | Website: traulsen.com Form Number: TR35743 | Part Number: 375-60176-00 | Revision Date: 11-16-20 Hours of Operation: Monday - Friday 7:30 a.m. - 4:30 p.m. (CST)

This manual is also suitable for:

A series