All Traulsen units are placed on a permanent record file with the service department. In the event of any future questions you may have, please refer to the model and serial number found on the name tag affixed to the unit.
The serial tag is a permanently affixed sticker on FORT WORTH, TX. which is recorded vital electrical and refrigeration data about your Traulsen product, as well as the model SERIAL MODEL and serial number. This tag is located in the upper...
The carton is attached to the Please note that Traulsen units are not designed to be wooden skid with the use of large staples. These moved while on legs. If the unit requires moving, a...
In order to assure optimum performance, the condens- load, or up to twenty eight (28) 18” x 26” pans of product. ing unit of your Traulsen unit MUST have an adequate supply of air for cooling purposes. Therefore, the oper- Use of aluminum pans is highly recommended.
The Traulsen Even-Thaw model is preset at the factory The most important thing you can do to insure a long, to operate within strict temperature parameters. Should reliable service life for your Traulsen is to regularly clean these settings require adjustment, please contact our the condenser coil.
For your convenience, the warranties on your new surface. Do NOT use cleansers containing chlorine, Traulsen unit may be registered with us by one of two this may promote corrosion of the stainless steel. methods. Completing the enclosed warranty card...
VI. a - INTRODUCTION/OVERVIEW: The Even-Thaw model can accommodate any size The Traulsen Even Thaw is designed to be used as a partial load, or up to (28) 18” x 26” pans of product (for thawing cabinet. While it may be utilized in a example approximately 672 lbs.
VIII. b - TEST PARAMETERS: several system checks which can be done to diagnose To provide a general performance baseline, Traulsen the Traulsen Even-Thaw unit. performed some controlled testing in our lab which...
IX. TROUBLE SHOOTING GUIDE FIND YOUR PROBLEM HERE REMEDY 1. Condensing unit fails to start. Check if cord & plug has been disconnected. Call for service. 2. Condensing unit operates for Are doors closing properly? prolonged periods or continuously. Dirty condenser or filter. Clean properly. Evaporator coil iced.
X. SPARE PARTS LIST TWO SECTION REACH-IN EVEN-THAW MODELS PART NUMBER NAME OF PART 200-60139-01 Full Height Stainless Steel Door (hinged left) 200-60139-00 Full Height Stainless Steel Door (hinged right) 341-09501-00 Gaskets For Above 325-60003-03 Filter Drier (DCL 082S) 325-60080-07 TXV Valve 134a 326-60102-00 1/4 Hot Gas Tubing...
TRAULSEN’S standard warranty does not apply to Export Sales. Rather, for a period of one (1) year from date of original installation not to exceed Fifteen (15) months from date of shipment from factory, TRAULSEN: will replace, F.O.B.
Page 14
XIV. INDEX Mullion Air Ducts Batch Loading Blower Switch Operational Troubleshooting Call Service Light Cleaning 5 - 6 Casters Power Supply Cord & Plug Process Loading Clearance Product Mix - Issues Condenser, Cleaning The Refrigerations System Return Authorization Even-Thaw Operation Evaporator Outlet Serial Tag Extended Thaw Times, Causes Of...