CAUTION:
(4.5 m) in length, to comply with National Electrical Code (NEC) Sections 400-8 (NFPA
75, 5-2.2) and 210-52, and Canadian Electrical Code (CEC) Section 4-010(3). The cords
supplied with the router are in compliance.
CAUTION:
location. It has a separate protective earthing terminal (size for UNC 1/4-20 ground
lugs) provided on the chassis in addition to the grounding pin on the power cord. This
separate protective earthing terminal must be permanently connected to earth.
CAUTION:
drape where people could trip on them.
SEE ALSO
Preventing Electrostatic Discharge Damage to an MX2008 Router | 544
Replacing an MX2008 AC Power Supply Module | 422

MX2008 AC Power System Electrical Specifications

NOTE:
The MX2008, MX2010, and MX2020 routers support the same power modules (AC/DC
PSMs and AC/DC PDMs).
Table 29 on page 86
lists the AC power system electrical specifications for the MX2000 line of routers.
In North America, AC power cords must not exceed approximately 14.75 ft
The router is pluggable type A equipment installed in a restricted-access
Power cords and cables must not block access to device components or
85