MX2008 Three-Phase Delta AC Power Distribution Module Electrical
Specifications
NOTE:
The MX2008, MX2010, and MX2020 routers support the same power modules (AC/DC
PSMs and AC/DC PDMs).
Table 31 on page 89
lists the three-phase delta AC power distribution monitor (PDM) electrical
specifications.
Table 31: Three-Phase Delta AC Power Distribution Module Electrical Specifications
Item
AC input voltage
AC input line frequency
AC input current rating
AC system input power
Efficiency
SEE ALSO
MX2008 AC Power Requirements | 74
Preventing Electrostatic Discharge Damage to an MX2008 Router | 544
MX2008 AC Power Cord Specifications | 82
Specification
Operating range: 200–240 VAC (line-to-line) (nominal)
50/60 Hz (nominal)
50 A @ 200 VAC (input #1 for each PDM)
25 A @ 200 VAC (input #2 for each PDM)
16800 W (input #1), 8400 W (input #2)
90.5% at 50% load and 220 VAC IN