Mains connection Compax3S0xxV2 1AC
Controller type
Continuous working voltage
Receiver current consumption
Maximum fuse rating per device
Mains connection Compax3S1xxV2 3AC
Controller type
Supply voltage
Input current
Maximum fuse rating per device
Mains connection Compax3SxxxV4 3AC
Controller type
Continuous working
voltage
Receiver current
consumption
Maximum fuse rating per
device
Control voltage 24VDC Compax3S and Compax3H
Controller type
Voltage range
Current drain of the device
Total current drain
Ripple
Requirement according to safe extra
low voltage (SELV)
Short-circuit proof
Output data Compax3S0xx at 1*230VAC/240VAC
Controller type
Output voltage
Nominal output current
Pulse current for 5s
Power
Switching frequency
Power loss for In
192-120102 N19 June 2014
S025V2
Single phase 230VAC/240VAC
80-253VAC / 50-60Hz
6Arms
10 A (automatic
circuit breaker K)
S100V2
Three phase 3* 230VAC/240VAC
80-253VAC / 50-60Hz
10Arms
16A
MCB miniature circuit breaker, K characteristic
S015V4
S038V4
Three phase 3*400VAC/480VAC
80-528VAC / 50-60Hz
3Aeff
6Arms
6A
10A
MCB miniature circuit breaker, K characteristic
Compax3
21 - 27VDC
0.8 A
0.8 A + Total load of the digital outputs + current
for the motor holding brake
0.5Vpp
yes
conditional (internally protected with 3.15AT)
S025V2
3x 0-240V
2.5Arms
5.5Arms
1kVA
16kHz
30W
Signal interfaces
S063V2
13Arms
16A (automatic circuit
breaker K)
S150V2
13Arms
20A
S075V4
S150V4
S300V4
10Arms
16Arms
22Arms
16A
20A
25A
S063V2
3x 0-240V
6.3Arms
12.6Arms
2.5kVA
16kHz
60W