Parker EME
3.4.2.

Connector and pin assignment C3S

Overview:
Caution - Risk of Electric Shock!
Always switch devices off before wiring them!
Dangerous voltages are still present until 10 min. after switching off the power
supply.
Caution!
When the control voltage is missing there is no indication whether or not high
voltage supply is available.
Attention - PE connection!
PE connection with 10mm
Attention - hot surface!
The heat dissipater can reach very high temperatures (>70°C)
Line cross sections of the line connections X1, X2, X3
Compax3 device:
S025V2, S063V2
S100V2, S150V2
S015V4, S038V4, S075V4, S150V4
S300V4
AC - Versorgung
AC - Supply
DC - Versorgung
DC - Supply
Freigabe 24VDC
Enable 24VDC
Further information on the assignment of the plug mounted at the particular
192-120102 N19 June 2014
2
via a grounding screw at the bottom of the device.
Cross-section: Minimum... Maximum[mm
0.25 ... 2.5 (AWG: 24 ... 12)
0.25 ... 4 (AWG: 24 ... 10)
0.5 ... 6 (AWG: 20 ... 7)
Compax3
X1
X10
X4 (24VDC)
X4/3
device can be found below!