Compax3 Device Description; State Of Delivery; Meaning Of The Status Leds - Compax3 Axis Controller - Parker Compax3S Series Installation Manual

Single axis devices
Hide thumbs Also See for Compax3S Series:
Table of Contents

Advertisement

Parker EME

3. Compax3 device description

3.1

State of delivery

3.2

Meaning of the status LEDs - Compax3 axis controller

In diesem Kapitel finden Sie
State of delivery ............................................................................................................... 17
Meaning of the status LEDs - Compax3 axis controller .................................................... 17
Mounting and dimensions ................................................................................................ 18
Connections of Compax3S .............................................................................................. 22
Signal interfaces .............................................................................................................. 31
Compax3 is delivered without configuration!
After switching on the 24VDC supply, the red LED is flashing while the green LED is
dark.
Please configure the device with the help of the Windows-Software "Compax3
ServoManager"!
Device status LEDs
Voltages missing
During the booting sequence
No configuration present.
©
SinCos
feedback not detected.
Compax3 IEC61131-3 program not
compatible with Compax3 Firmware.
no Compax3 IEC61131-3 program
Hall signals invalid.
Axis powerless
Power supplied to axis; commutation calibration
running
Axis powered
Axis in error state / error present / axis powered
(error reaction 1)
Axis in error state / error present / axis not powered
(error reaction 2)
Compax3 faulty: Please contact us
192-120102 N19 June 2014
State of delivery
Right LED (red)
Left LED (green)
off
off
alternately flashing
flashes slowly
off
off
flashes slowly
off
flashes quickly
off
on
flashes quickly
on
on
off
on
on
17

Advertisement

Table of Contents
loading

Table of Contents