Compax3Sxxx V4 - Parker Compax3S Series Installation Manual

Single axis devices
Hide thumbs Also See for Compax3S Series:
Table of Contents

Advertisement

Parker EME
3.4.6.

Compax3Sxxx V4

Device protection
Caution!
In diesem Kapitel finden Sie
Power supply connector X1 for 3AC 400VAC/480VAC-C3S devices ............................... 29
Braking resistor / high voltage supply connector X2 for 3AC 400VAC/480VAC_C3S devices
Connection of the power voltage of 2 C3S 3AC devices .................................................. 30
3.4.6.1
Power supply connector X1 for 3AC
400VAC/480VAC-C3S devices
By cyclically switching on and off the power voltage, the input current
limitation can be overloaded, which will cause a device error.
Therefore please wait at least 2 minutes after switching off before you switch
PIN
Designation
1
L1
2
L2
3
L3
4
PE
Mains connection Compax3SxxxV4 3AC
Controller type
Continuous working
voltage
Receiver current
consumption
Maximum fuse rating per
device
* for UL conform operation (see on page 14), a miniature circuit breaker, K
characteristic, Type S203 is to be used.
The 3AC V4 devices must only be operated with three phases!
Caution - Risk of Electric Shock!
Always switch devices off before wiring them!
Dangerous voltages are still present until 10 min. after switching off the power
supply.
3.4.6.2
Braking resistor / high voltage supply connector X2
for 3AC 400VAC/480VAC_C3S devices
PIN
Description
1
+ Braking resistor
2
- Braking resistor
3
PE
4
+ DC high voltage supply
5
- DC high voltage supply
192-120102 N19 June 2014
the device on again!
S015V4
S038V4
Three phase 3*400VAC/480VAC
80-528VAC / 50-60Hz
3Aeff
6Arms
6A
10A
MCB miniature circuit breaker, K characteristic
no short-circuit
protection!
Connections of Compax3S
S075V4
S150V4
S300V4
10Arms
16Arms
22Arms
16A
20A
25A
29
D*
29

Advertisement

Table of Contents
loading