Conditions Of Utilization; Conditions Of Utilization For Ce-Conform Operation - Parker Compax3S Series Installation Manual

Single axis devices
Hide thumbs Also See for Compax3S Series:
Table of Contents

Advertisement

Introduction
2.7

Conditions of utilization

2.7.1.

Conditions of utilization for CE-conform operation

Mains filter:
Compax3S motor
cable
12
In diesem Kapitel finden Sie
Conditions of utilization for CE-conform operation ........................................................... 12
Conditions of utilization for UL certification Compax3S .................................................... 14
Current on the mains PE (leakage current) ...................................................................... 15
Supply networks .............................................................................................................. 15
- Industry and trade -
The EC guidelines for electromagnetic compatibility 2004/108/EC and for electrical
operating devices for utilization within certain voltage limits 2006/95/EC are fulfilled
when the following boundary conditions are observed:
Operation of devices only in the state in which they are delivered.
In order to ensure contact protection, all mating plugs must be present on the device
connections even if they are not wired.
Please respect the specifications of the manual, especially the technical
characteristics (mains connection, circuit breakers, output data, ambient
conditions,...).
2.7.1.1
Conditions of utilization mains filter
A mains filter is required in the mains input line if the motor cable exceeds a certain
length. Filtering can be provided centrally at the system mains input or separately for
each device.
Use of the devices in a commercial and residential area (limit value class in
accordance with EN 61800-3)
The following mains filters are available for independent utilization:
Device:
Compax3S
S0xxV2
S1xxV2,
S0xxV4, S150V4
S300V4
Connection length: Connection between mains filter and device:
unshielded:
< 0.5 m
shielded
< 5 (fully shielded on ground - e.g. ground of control cabinet)
2.7.1.2
Conditions of utilization for cables / motor filter
Operation of the devices only with motor and feedback cables whose plugs contain a
special full surface area screening.
< 100 m (the cable should not be rolled up!)
A motor output filter is required for motor cables >20 m:
MDR01/04 (max. 6.3 A rated motor current)
MDR01/01 (max. 16 A rated motor current)
MDR01/02 (max. 30 A rated motor current)
192-120102 N19 June 2014
Limit value
Motor cable length
class
C2
< 10 m
C2
> 10 m, < 100 m
C2
< 10 m
C2
> 10 m, < 100 m
C3
< 10 m
C2, C3
> 10 m, < 100 m
Single axis devices
Mains filter
Order No.:
without
NFI01/01
without
NFI01/02
without
NFI01/03