List Of Warning Massages - Roland DPX-3700A User Manual

Drafting plotter
Table of Contents

Advertisement

Computer
Is the computer set up correctly?
Check the following items:
• DIP switches
• Memory switches
Read the computer user's manual and set it up correctly.
Connection cable
Are the computer and the plotter linked with the right cable?
The type of cable you need is determined by your computer and the software you are using. Even if the computer is
the same, running different software may require a different cable. Use the cable specified in your software.
Is the cable making a secure connection?
Connect securely.
Software
Is the OS (Operating System) set up correctly?
Check the following items:
• Output port selection
Check the OS user's manual and set it up correctly.
Are the application software settings correct?
Check the following items:
• Output device specification (select a plotter name that matches the instruction system. If the wrong plotter is
selected an incorrect instruction may be output, resulting in an error).
• Communication parameters
Check the software user's manual and set it up correctly.
List of Warning Messages
Warning message
Wrong Angle
Failed to Set
Out of Area
Can Not Offset
Pen Change Error
Power On again
Take off Pen
then Push ENTER
Set Pen
then Push ENTER
Put 0.3mm Lead
then Push ENTER
Too Big Data
Can not Replot
Motor Error
Power On again
Caution
Can not Replot
• Interface board
• Output device selection
• Other
The axis-alignment angle is supported up to ±5 degrees.
First set the paper and then correct the angle.
The maximum plotting range cannot exceed the plotting range for the set paper
size.
The offset should be set so that plotting is within the maximum plotting range.
Pen changeover failed. Turn off the power, check the situation of the pens and
pen installation and then turn on the power again.
The pen cannot be installed directly onto the pen carriage.
Remove the pen and press
No pens are available in the pen stock.
Install pens in the pen stock and press
The pencil lead has run out. Fill the pencil with new leads and press
Replot and area plot are not supported when plotting data exceeds 1 Mbyte.
Clear the DPX I/O buffer using the [Clear] menu selection and retransmit the
data from the computer.
A malfunction has occurred with the motor. Turn off the power and turn it on
again.
Replot (area plot) cannot be performed.
37
• Other
• Output port open
• Other
Remarks
.
.
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dpx-2700a

Table of Contents