Load A Compile Cycle; Interface Version Compatibility - Siemens SINUMERIK 840Di sl Commissioning Manual

Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

11.8.1

Load a compile cycle

Requirement
To transfer the compile cycle to the control, the following requirements must be met:
● There is a network connection (TCP/IP) between the PCU and an external computer
● Storage media can be connected to the PCU (e.g. USB FlashDrive) on which the compile
Implementation
Perform the following operation to load one or more compile cycles into the NC:
1. End the active SINUMERIK user interface (e.g. HMI Advanced) and activate the
2. Use Windows Explorer to copy the compile cycle file (e.g. ccresu.elf) from the external
3. Trigger an NC reset to load the compile cycles into the NC system software.
11.8.2

Interface version compatibility

A SINUMERIK-specific interface is used for communication between the compile cycle and
NC system software. Therefore, the interface version of a loaded compile cycle must be
compatible with the interface version of the NC system software. Each interface version is
displayed under:
● Interface version of the NC system software
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
(PC/PG) on which the compile cycle is located.
cycle is saved.
SINUMERIK desktop (see Chapter "Activation" (Page 135)).
computer (PC/PG) or the CD/disk drive to the following directory on the PCU:
F:\card\oem\sinumerik\oa\
HMI Advanced:
Diagnosis > Service Display > Version > NCU Version
Display (excerpt)
NC Commissioning with HMI Advanced
11.8 Loadable compile cycles
479

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840die sl control

Table of Contents