7.7.2
Linking to the basic PLC and user program
7.7.2.1
Interface signals
Number system
The following figure shows the number system of the softkeys and LED of the HT 2 operator
field.
Figure 7-12
Note
In order to transfer the user softkeys (SK1, SK6, SK11 and SK16) in the input interface, at
least version 8.2 of the software "PCU-Base" must be installed.
NO LEDs are available at the HT 2 for the user softkeys (SK1, SK6, SK11 and SK16).
Input image
The address specification of the input image EB takes place in the FB 1 function module,
parameters: "HHUIn".
Table 7-8
Assignment of the signals in the input image
Signals from HT 2
Byte
Bit 7
EB m + 0
EB m + 1
EB m + 2
SK8
EB m + 3
-
EB m + 4
SK25
EB m + 5
Write
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Numbering of the softkeys and LEDs
Bit 6
Bit 5
-
SK7
SK12
SK20
SK14
SK13
Key-
Bit 4
Bit 3
Reserved
Reserved
SK5
SK4
SK19
SK18
-
-
Rotary coding switch (override) 1)
Ethernet communication
Bit 2
Bit 1
SK3
-
SK17
SK10
-
-
7.7 HT 2
Bit 0
SK2
SK9
-
-
223