Siemens SINUMERIK 840D sl Commissioning Manual page 78

Hmi-embedded im2
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Creating user-specific alarm texts
4.3 Syntax of the text file
Display
This number defines the alarm display type:
0: Display in alarm line
1: Display in a dialog box
Help ID
Since help is not displayed with HMI-Embedded, a "0" always has to be entered.
Text or alarm number
Characters " and # must not be used in alarm texts. The % character is reserved for
displaying parameters.
If an existing text is to be used, this can be done with a reference to the corresponding
alarm. 6-digit alarm number instead of "text".
● The maximum length of the alarm/message text is 110 characters in total for a 2-line
Parameter
"%K":
Parameter
"%A":
Parameter
"%N":
Parameter
"%Z":
Note
The alarm number is output by the PLC via basic program module FC 10. (This uses PLC
system function SFC 52 to send alarms to HMI-Embedded). Supplementary information is
not supported.
However, the alarm number can also be transferred to HMI-Embedded by means of PLC
system function SFC 17, SFC 18 (ALARM S, ALARM SQ). The mechanisms are used, for
example, by the PDIAG configuring tool.
The alarm number (displayed by HMI-Embedded) is transferred via SFC parameter EV_ID.
The supplementary information for the alarm number is transferred via SFC parameter SD.
78
display. If the text is too long, it is truncated and the symbol "/*/" added to indicate missing
text. The entries should be separated from one another by blanks.
= 0, e.g., channel number with FC10
(As substitute for %K, the 2nd digit of the 6-digit alarm number is
inserted in the alarm text). Digit count from left to right.
= 24, the parameter is replaced by the signal group no. (e.g., axis no.,
user area no., sequence cascade no.)
(As substitute for %A, the 3rd and 4th digits of the alarm number are
inserted in the alarm text).
= 63, e.g., signal number
(As substitute for %N, the 5th and 6th digits of the alarm number are
inserted in the alarm text).
e.g., status number for Higraph
(As substitute for %Z, the supplementary information for the alarm
number is inserted in the alarm text. This parameter is only relevant in
conjunction with HIGRAPH programming 800000...899999).