5. Disconnect the SMALL connector toward the back of the Puncture Mechanism module area. If
it is easier, you can remove the Puncture Mechanism Module completely to gain access to this
connector.
6. Carefully pull the wire through the opening in the chassis and remove the RIGHT side bin
sensor.
7. This completes the RIGHT side bin sensor removal. Install the replacement sensor making sure
that all connections are tight. Attach the Puncture Mechanism Module cover and tighten its
retaining screws.
8. Conduct a BIT test (see appendix VII on page 85) to insure the proper function of the brewer.