C. PUNCTURE MECHANISM MODULE (Located in the top front portion of the brewer)
See REMOVAL of OUTER PANELS (page 36). After completion of panel removal, the technician
must attach an ESD wrist strap to themselves and the metal base plate of the brewer.
1. Disconnect the Hot Water Valve tube from the top of the Bottom Hot water tank.
This hose is on the right hand side of the brewer looking at the front of the brewer.
BREWERS ≤ 7505
2. Raise the Puncture Mechanism handle and locate the two screws that hold the Puncture
Mechanism cover in place.
3. Remove these screws.
4. Push the cover back slightly and lift up to remove.
Looking at the front of the brewer,
B3000 SERVICE MANUAL
60-200807-000, REV C
BREWERS ≥ 7506
41