Time Program - Viessmann Vitotronic 200 Series Operating Instructions For The System User

Heating system with weather-compensated control unit
Table of Contents

Advertisement

Time program

The following explains how to input the settings for a
time program. The special features of each individual
time program are assigned to the relevant chapters.
You can set up a time program for the following func-
tions:
Central heating (see page 23)
DHW heating (see page 28)
DHW circulation pump (see page 29)
In the time program, divide the day into sections.
These are called time phases. It is for you to decide
what happens in these time phases. For example, they
could specify when your rooms will be heated to stand-
ard room temperature.
Setting a time program using central heating as an example
Extended menu:
1.
2. "Heating"
3. If necessary, / for the required heating circuit.
4. "Heating time program"
5. Select part of the week or a day.
6. Select a time phase
!
phase is illustrated by a white bar on the time chart.
7. Set the start and end points for the relevant time
phase. The length of the white bar in the time dia-
gram is adjusted accordingly.
8. Press
to exit the menu.
Note
If you want to terminate a time phase setting process
prematurely, keep pressing
play appears.
Example of time phases within the time program
for central heating
!
Heating
Mo-Fr
0
2
4
6
8
10 12 14 16 18 20 22 24
05:00 - 08:30
!
16:30 - 23:00
?
Select with
Fig. 10
to
. The selected time
$
until the required dis-
?
HC1
Normal
u
Normal
u
(
You can set the time program individually, to be the
same, or different, for every day of the week.
You can select up to 4 time phases per day.
For each time phase you select the start and end
points.
The selected time phase is illustrated by a white bar
on the time chart. The length of the bar reflects the
length of time.
In the extended menu, you can call up the time pro-
grams under "Information" (see page 33).
Time program for the following part of the week:
"Monday
Friday" ("Mo-Fr")
Time phase
:
!
05:00 to 08:30 h
Time phase
?
:
16:30 to 23:00 h
In between these time phases the system heats to a
reduced temperature.
Operation
17