Dhw Temperature - Viessmann Vitotronic 200 Series Operating Instructions For The System User

Heating system with weather-compensated control unit
Table of Contents

Advertisement

DHW heating

DHW temperature

Factory setting: 50 °C
Extended menu
1.
2. "DHW"
Operating program
Further information can be found in chapter
"Terminology" in the appendix.
Setting the operating program for DHW heating
For the preferred heating circuit
Standard menu
1. / for the operating program:
"Heating and DHW"
Or
"Only DHW"
2. OK to confirm.
For all heating circuits
Extended menu
1.
2. "Heating"
Time program
Further information can be found in chapter
"Terminology" in the appendix.
Setting the time program for DHW heating
Factory setting: One time phase from 05:30 to 22:00 h
for every day of the week.
Extended menu:
1.
2. "DHW"
3. "DHW time prog"
4. Set the required time phases.
To see how to set a time program, see page 17.
DHW heating once, no longer in the time program
Note
The operating program "Heating and DHW" or "Only
DHW" must be set for at least one system heating cir-
cuit.
28
3. "Set DHW temperature"
4. Set the required value.
3. If necessary, / for the required heating circuit.
4. "Heating program"
5. "Heating and DHW"
Or
"Only DHW"
For information on the operating programs, see
page 16.
Note
Between the time phases, DHW is not heated; only
frost protection for the DHW cylinder is active.
When setting time programs, please bear in mind
that your heating system requires some time to heat
the DHW cylinder to the required temperature.
Extended menu
1.
2. "Heating"
3. "Party mode"
4. Disable "Party mode" again with "OFF" to prevent
unintentional central heating with standard room
temperature.