Furuno 1824C-BB Installation Manual page 51

Marine radar and color video plotter
Hide thumbs Also See for 1824C-BB:
Table of Contents

Advertisement

33. The next step is to choose navigation data sources and calibrate navigation data. Press
the A: NEXT soft key to show the NAV SETUP menu.
POSITION SOURCE
SPEED SOURCE
TEMPERATURE SOURCE
DETPH SOURCE
STW CALIBRATION
TEMP CALIBRATION
DEPTH CALIBRATION
WIND AVERAGING
WIND DIRECTION OFFSET
WIND SPEED CALIBRATION +00%
STW
TEMP
12.3 kt
WIND SPEED
WIND DIR
1.2 kt
Installation wizard, nav setup
34. Choose item and press the C: EDIT soft key.
35. Choose appropriate setting and then press the C: ENTER soft key. Refer to the table
below for description of each item.
Item
Description
Position
Chooses source of position data.
Source
Speed
Chooses source of speed data
Source
Temperature
Chooses source of water temperature data.
Source
Depth Source Chooses source of depth data.
STW
Calibrates NMEA speed data. Enter amount
Calibration
in percentage.
Temp
Calibrates NMEA temperature data. Enter
Calibration
offset to correct NMEA temperature data.
Depth
Calibrates NMEA depth data. Enter offset to
Calibration
correct NMEA depth data.
Wind
Enter a value to smooth wind speed/direction
Averaging
data. Ship's bow is referenced to smooth
wind vector movement.
Wind
Offsets wind direction data.
Direction
Offset
Wind Speed
Offsets NMEA wind speed data. Enter
Calibration
amount in percentage.
GP
ETR
ETR
ETR
+00%
+00.0°F
+00ft
001 seconds(s)
S000.0°
DEPTH
56.3°F
99.5ft
131°
NAV SETUP menu description
Settings (Default in boldface)
FURUNO BB GPS: GPS Receiver
GP-310B/320B
GP: GPS navigator (via NETWORK
or NMEA port)
LC: Loran C navigator (via
NETWORK or NMEA port)
ALL: Multiple navaid connection (via
NETWORK or NMEA port)
ETR (NavNet sounder), NMEA
ETR, NMEA. Select ETR to show
water temperature data fed from the
network sounder.
ETR, NMEA. Select ETR to show
depth data fed from the network
sounder.
-50 to +50%, 00
-40.0°F to +40.0°F (or equivalent
in °F), 00.0°F
-15 to +90 ft (or equivalent in ft, fa
or P/B). 00 ft
001-600 s, 001 s
S180°-P180°, S000.0°
-50 to +50%, 00%
3-7