How to fasten the radome base to the mounting platform
Wiring and final preparations
4. Drill a hole of approx. 16 mm diameter through the deck or bulkhead to run the signal
cable between the antenna unit and the display unit. (To prevent electrical interference
avoid running the signal cable near other electrical equipment and in parallel with power
cables.) Pass the cable through the hole. Then, seal the hole with sealing compound for
waterproofing.
5. Remove two shield covers in the radome.
6. Remove the cable clamping plate by unfastening four screws and removing a gasket.
Shield cover
Pan head screws
M4x8
7 pcs.
Shield cover
Pan head screws
M4x8 7 pcs.
7. Pass the cable through the hole at the bottom of the radome base.
8. Secure the cable with the cable clamping plate and gasket. Ground the shield wire by
one of the screws of the cable clamping plate.
Effective
thread length
25 mm
Flat
washer
Spring
washer
Apply silicone sealant.
Cable clamping plate
Antenna unit, inside view
Antenna base plate
Gasket
Radome
5 - 10 mm
Platform
M10 x 25
Hex bolt
Pan head screws
M4x8 4 pcs.
Gasket
1-14