Pin
7
8
9
10
11
12
13
14
Connection notes
1. Recommended connection:
2. Not recommended connection:
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
Signal name
M2
MEXT2
P1
P24EXT1
IO12
DI/DO12
IO13
DI/DO13
M1
MEXT1
IO14
DI/DO14
IO15
DI/DO15
M1
MEXT1
If both inputs and outputs are operated on a digital inputs/outputs group, it is recommended
that both the inputs and the outputs are fed with the same 24 VDC supply:
Figure 6-2
Inputs and outputs on the same supply
If the inputs and outputs supplied separately with power, the input current can exceed the
permissible value of 15 mA according to EN61131-2. This may possibly cause the signal
source to be overloaded:
Figure 6-3
Inputs and outputs on different supplies
Meaning
Ground for pins 1...6
+24 V power supply
Digital input/output 12
Digital input/output 13
Ground for pins 9, 10, 12, 13
Digital input/output 14
Digital input/output 15
Ground for pins 9, 10, 12, 13