Figure 7-3
After switching on, the motor accelerates to the setpoint, jog 1 or setpoint, jog 2. The two
different setpoints can, for example, be assigned to motor clockwise and counter-clockwise
rotation.
When jogging, the same ramp-function generator is active as for the ON/OFF1 command.
Jog settings
Parameter
p1058
p1059
p1082
p1110
p1111
p1113
p1120
p1121
p1055 = 722.0
p1056 = 722.1
SIMATIC ET 200pro FC-2 converter
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257324B AE
Behavior of the motor when "jogging"
Description
Jogging 1 speed setpoint (factory setting 150 rpm)
Jogging 2 speed setpoint (factory setting -150 rpm)
Maximum speed (factory setting 1500 rpm)
Inhibit negative direction
=0: Negative direction of rotation is enabled =1: Negative direction of rotation is
Inhibit positive direction
=0: Positive direction of rotation is enabled
Setpoint inversion
=0: Setpoint is not inverted
Ramp-function generator ramp-up time (factory setting 10 s)
Ramp-function generator ramp-down time (factory setting 10 s)
Jog bit 0: Select jogging 1 via digital input 0
Jog bit 1: Select jogging 2 via digital input 1
Advanced commissioning
inhibited
=1: Positive direction of rotation is
inhibited
=1: Setpoint is inverted
7.3 Jogging
93