Disassembly; Servicing; Cleaning; Disposal - GEM 1230 Installation, Operating And Maintenance Instructions

Electrical position indicator with microswitches
Table of Contents

Advertisement

Available languages

Available languages

After completing the electrical
G
connection, pull the connection cable
taut; however, avoid pulling too hard.
Check the position of the sealing ring R.
G
Attach the cover H with the screws G.
G
Screw in the screws G.
G
Ensure all seals and threaded
G
connections are correctly
installed.
Supply power to the electrical position
G
indicator.
Open and close the process valve
G
to check the switching positions. If
the switching positions need to be
readjusted, switch off the power to the
electrical position indicator.

4.10 Disassembly

Switch off the power to the electrical
G
position indicator.
Version with socket:
Disconnect the plug.
G
Version with terminals:
Lift cover H.
G
Remove the individual wires from the
G
terminal strip.
Remove the connection cable.
G
Remove the electrical position indicator
G
and mounting kit in the opposite order to
the assembly procedure (see chapters
4.1 - 4.9).
5

Servicing

The operator must carry out visual
G
examinations regularly.
Version with terminals:
Regularly check that the individual
G
wires and connection cable are seated
correctly.
6

Cleaning

Never clean the electrical position
indicators with a high-pressure
cleaning device.
Otherwise, you risk damaging the
®
electrical position indicator.
Observe the protection class
G
(IP 65 acc. to EN 60529)!
Clean the electrical position indicator with
G
a damp cloth or gentle stream of water.
7

Disposal

Disposal of the individual components
should be separated by materials (materials
see below), circuit boards with electronic
components and travel sensor placed in
electronics scrap.