General To The Conduit In Tcs Audio Systems; Principle Loop Resistance; Resistance Measurement - TCS ISH3030 Product Information

Hide thumbs Also See for ISH3030:
Table of Contents

Advertisement

07/2013
General information on the conduit in TCS audio systems
The conduit is determined by structural conditions and is only limited by ist length.
 Note when selecting the cables: the loop re-
sistance can amount max. 20 Ω (table)
 In compliance to the max. permitted loop re-
sistance the wire cross-section can be doubled,
that means, that for one wire two lines can be
used. The lines have to be twisted.
 In case of using shielded cables: connect the
shielding with each other and put it one-sided on
mass (b-wire) in the power supply
 Optional strand or star formed wiring
table: loop resistances
cable length in m
10
20
30
40
50
60
70
80
90
100
150
200
250
300

Principle loop resistance

None of these devices (AS, IS or FE) should be
located more than 20 Ohm away from the power
supply and control unit (VS).
TCS TürControlSysteme AG
Mail: hotline@tcsag.de
13
line diameter
0.6 mm
loop resistance in Ω
1.28
2.55
3.83
5.10
6.38
7.65
8.93
10.20
11.48
12.76
19.13
25.51
31.89
38.27

Resistance measurement

 Switch off 230 V / 50 Hz of the VS.
 Install a-b short-circuit at VS.
 Other devices don't disturb the measurement,
they can be connected.
 Measure the resistance at a/b of the last IS or AS.
0.8 mm
0.71
1.43
2.14
2.86
3.57
4.29
5.00
5.71
6.43
7.14
10.71
14.29
17.86
21.43
Subject to technical changes.
ISH3030-0140 UK
2A

Hide quick links:

Advertisement

Table of Contents
loading