General Notes On The Cabling In Tcs Audio Systems - TCS PDS Series Product Information

Front-door station series for surface-mounting
Table of Contents

Advertisement

PI_GB_PES_PDS_Art0015689_1v0.doc 4

General notes on the cabling in TCS audio systems

The cabling depends on the building situation and is only limited by its length.
• When selecting the cable length consider: the
loop resistance must not exceed max. 20 Ω (ta-
ble)
• To keep within the max. permissible loop resis-
tance the wire cross section can be doubled, i.e.
two lines are used for one wire (figure). The li-
nes must be twisted.
• When using screened cables: connect the
screens to each other and connect on one side
to earth (b wire) on the power supply unit
• Choice of line or star wiring
Table: loop resistances
Cable length in m
10
20
30
40
50
60
70
80
90
100
150
200
250
300
TCS TürControlSysteme AG • Geschwister-Scholl-Str. 7 • 39307 Genthin
Phone: +49 39 33 / 87 99 10 • Fax: +49 39 33 / 87 99 11 • www.tcs-germany.com
rt
= red
gn
= green
bl = blue
br
= brown
ws = white
sw
= black
ge = yellow
0.6 mm²
1.22
2.45
3.67
4.90
6.12
7.35
8.57
9.80
11.02
12.24
18.37
24.49
Cable cross section
Loop resistance in Ω
0.69
1.38
2.07
2.76
3.44
4.13
4.82
5.51
6.20
6.89
10.33
13.78
17.22
20.66