Displaying Alarms Present On Your Switch - HP 12500 Series Installation Manual

Routing switch
Table of Contents

Advertisement

Temperature: 26 C
High temperature alarm threshold: 60 C
Low speed alarm threshold: 1450 rpm
Fan
Status
---
----------
1
normal
2
normal
3
normal
4
normal
5
normal
6
normal
7
normal
8
normal
9
normal
10
normal
11
normal
12
normal
Table 19 Command output
Field
Fan-tray 1:
Speed(rpm)
Fan-tray verbose state on chassis 1:

Displaying alarms present on your switch

Use the display alarm command to display the alarming information about your switch.
In standalone mode:
<Sysname> display alarm
Slot
6
6
6
3
Table 20 Command output
Field
Slot
Level
Info
faulty
Speed(rpm)
----------
4300
4350
4050
4350
4350
4350
4400
4100
4200
4100
4300
4350
Level
Info
ERROR
Fan 2 is absent.
ERROR
Power 2 is absent.
ERROR
The board in slot 10 is faulty.
WARNING
The temperature of sensor 3 exceeds the lower limit.
Description
Indicates that the following information is for the fan in
tray number 1.
Rotate speed of the fan
Indicates that the following information is for the fan on
member switch 1
Description
Slot number of the alarmed card.
If the value is a hyphen (-), the alarm is generated by the chassis.
Alarm severity. Possible values include ERROR, WARNING,
NOTICE, and INFO, In the descending order.
Detailed alarm information.
The card is starting up or faulty.