HP 12500 Series Installation Manual page 113

Routing switch
Table of Contents

Advertisement

NOTE:
The AC power frame and power monitor module are integrated to the chassis of 12500 AC models, so
you do not need to order them. You must order the PEM and AC power supplies yourself.
The DC power frame and power monitor module are integrated to the chassis of 12500 DC models, so
you do not need to order them. You must order the DC power supplies yourself (PEM is not needed for
the DC power system).
Table 41 Electrical parameters of power supplies
Rated input voltage
Power supply
range
100 VAC to 120 VAC;
50 Hz or 60 Hz
AC power
supply
200 VAC to 240 VAC;
50 Hz or 60 Hz
DC power
–48 VDC to –60 VDC
supply
Table 42 16A AC power cords used in different countries or regions
Connector
Code (Length)
type
04043396 (3
I type
m, i.e., 9.8 ft)
1
Connector outline
Connector
Code (Length)
type
2
0404A063 (3
B type
m, i.e., 9.8 ft)
Connector outline
Max input voltage
range
90 VAC to 264
VAC; 47 Hz to 63
Hz
–42 VDC to –72
VDC
Countries or regions
where the type of
power cords conforms
to local safety
regulations and can be
used legally
Mainland China
Power cable outline
Countries or regions
where the type of
power cords conforms
to local safety
regulations and can be
used legally
Canada and U.S.A
Power cable outline
107
Max
input
Max output power
current
1200 W (100 VAC to 120
VAC)
13.3 A
2000 W (200 VAC to 240
VAC)
60 A
1800 W
Other countries or
regions using this type of
power cords
Other countries or
regions using this type of
power cords
Mexico, Argentina,
Brazil, Columbia,
Venezuela, Thailand,
Peru and Philippines
Countries or
regions seldom
using this type of
power cords
Connector outline
Countries or
regions seldom
using this type of
power cords
Connector outline

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

125081250412518